SP2nd is an economical gas detector that can be operated continuously for two years without replacement of gas sensor to protect workers from the disasters caused by the oxygen deficiency or toxic gas poisoning. easure one gas continuously and display its concentration and raise an alarm when a risk occurs.
Major Applications
Steelworks, Petrochemical plant, Shipbuilding yard, Sewage treatment plant, Mine, Power supply works, Hermetically sealed area (manhole, tank)
Features
01. Rubber material case for the shock protection
02. The excellent water proof/dust proof structure
03. High performance audible, visual, vibration alarm
04. Setting 1st, 2nd alarm
05. Automatic checking of the sensor trouble
06. Data logging
07. Disposable type (Under develoment)
08. BUREAU VERITAS Certification
09. RUSSIA Gost-R Certification
10. EUROPE electromagnetic waves fitness Certification
- Model SP2nd SP2227
- Measuring gas CO
- Measuring type Diffusion Type
- Measuring method Electrochemical cell
- Measuring range 0~500ppm
- Sensor life time > 2 year
- Response time < 30sec/90%scale
- Accuracy ์งน3%/Full scale
- Resolution 1ppm
- Parameter Control Front 2 switch(calibration, maintenance, alarm setting)
- Operation mode display Visual : Digital LCD display, Trouble RedLED
- Audible : buzzer(90dB @ 10cm)"
- Measuring value display LCD Display(3-digit)
- Alarm display Visual : alarm & status icon, Trouble RedLED
- Audible : buzzer"
- Alarm level set Programmable within dectection range
- Data Log Event Log : 20 Data
- Mounting type Belt Clip
- Program set mode Alarm value(1,2 alarm) , time Set, Calibration density setting
- Operating temperature -20��~50��
- Operating humidity 5% to 95% RH(Non-condensing)
- Operating power CR2 Lithium Battery 3V
- Battery life time CR2 Battery(3.0v) : 1.2year, At 8hours use of a day
- Materianl PC / TPE
- LCD size 27(W)*17.5(H)
- Dimensions 54(W) X 91(H) X 32(D) mm
- Weight 120g (Including Battery)
- Approval Ex ia IIC T4 IP67(KGS, ATEX)