Showing posts with label Gas. Show all posts
Showing posts with label Gas. Show all posts

Saturday, June 02, 2018

MQ-7B CO Gas Sensor

Gas sensor to detect carbon monoxide gas
Specifications:
- Power supply heater: 5V AC / DC
- Circuit power supply: 5VDC
- Measurement range: 20 - 2000ppm
- Able to measure carbon monoxide gas
- Output: analog (voltage change) with additional Rload

datasheet http: // zipansion • com / 6pcU

Saturday, September 10, 2016

TGS2603 Air Quality / Odor sensor

TGS2603 is a gas sensor which is suitable for application in the automotive, appliance air controller, and a smart home. This tool can detect gas contamination trimethylamine, methyl mercaptan and gases - other gases to the air we breathe.

specifications:
- Target gas: Trimethylamine, methyl mercaptan, and others - others
- The detection range: 1 - 10ppm EtOH
- The principle of sensing: MOS Type
- Heating Voltage: 5 V
- Circuit voltage: 5 V
- Power consumption: 20 mW
- Dimensions: 9.2 × 7.8mm
- Weight: 1 gr
- Features: Low power consumption, sensitivity tinngi against sulfur gas, using a simple electric circuit

Monday, January 25, 2016

MiCS-2714 NO2 MOS gas sensor

MICS 2714 this is a sensitive sensor to detect the levels of Nitrogen Dioxide (NO2) and hydrogen (H2).
With SMD packaging shapes, make us easy to use in projects that require small size.
This sensor can also be used to detect gas leaks.


Features:
- Size: 5 x 7 x 1.55 (mm).
- Suitable for the neighborhood / area factories / industries.

Saturday, October 03, 2015

TGS832-A00 Halocarbons gas sensor by Figaro

TGS832-A00 Halocarbons gas sensor by Figaro

Features

* High sensitivity to refrigerant gases
* Quick response
* Long term stability
* Uses simple electrical circuit

Application examples

* Portable and fixed installation refrigerant leak detectors

Specifications

Target gasesHalocarbon gas
Typical detection range10 - 1,000ppm
Sensing principleMOS type
Driving voltageHeater Voltage:5.0V
Circuit Voltage:Max24V
Power consumption835mW
Dimensionsφ17×10mm
WeightApprox. 2.4g

Saturday, July 11, 2015

HS-131 low cost nature gas sensor

HS-131 low cost nature gas sensor
High sensitive and good selectivity to fume and alcohol.
Long life and reliable stability.

HS-133 low cost Liquid Petroleum Gas sensor

HS-133 low cost Liquid Petroleum Gas sensor
High sensitive and good selectivity to fume and alcohol. 
Long life and reliable stability.

HS-134 low cost Carbon monoxcide sensor

HS-134 low cost Carbon monoxcide sensor 

High sensitive and good selectivity to low carbon monoxide concentration.
Long life and reliable stability.

Wednesday, January 21, 2015

M201 Air Quality Module

M201 adopts semi-conductor gas sensor and high performance MPU. It has Uart and I2C digital output and open set switch output. The module is applied to the development of the equipment for air quality detecting and controlling.


Application:
Air purifier, air pollution monitor, automatic vent device

Specification:
  • Target gas :Hydrogen
  • Detection range :20-150ppm
  • Sensor type :Semi-conductor
  • Response time :< 30s
  • Recovery time :< 50s
  • Working voltage :2.8-5.0V
  • Working current :< 120 mA
  • Output :Uart: Baud Rate 4800,n,8,1
  • Product Capability  :<15 li="" ppm="">
  • Precision :+/-15%(80ppm)
  • Expected lifespan :>2 years
  • Working condition :Temperature:0-55 C
  • Humidity:20%-90%RH
  • Storage condition :Temperature:-20-70 C
  • Humidity:20%-90%RH
  • External dimensions :25X24X18mm(LXWXH)

Tuesday, April 29, 2014

Low Cost Electronic modules Gas Sensor

MG811 Carbon Dioxide Sensor

MG811 Carbon Dioxide Sensor
Features:
  • Good sensitivity and selectivity to CO2
  • Low humidity and temperature dependency
  • Long stability and reproducibility

Application: 
  • Air Quality Control 
  • Ferment Process Control 
  • Room temperature CO2 concentration detection


Technical Parameters:
Symbol
Parameter Name
Technical
Remarks
VH
Heating Voltage
6.0±0.1 V
AC    or    DC
RH
Heating Resistor
30.0±5% Ω
Room Temperature
IH
Heating Current
200mA
PH
Heating Power
1200mW
Tao
Operating
-20—50℃
Tas
Temperature
-20—70℃
∆ E  M F
Storage Temperature
30—50mV
350—10000ppmCO2

MQ-9 Semiconductor Sensor for CO/Combustible Gas.

MQ-9 Semiconductor Sensor for CO/Combustible Gas


Sensitive material of MQ-9 gas sensor is SnO2, which with lower conductivity in clean air. It make detection by method of cycle high and low temperature, and detect CO when low temperature (heated by 1.5V). The sensor’s conductivity is more higher along with the gas concentration rising. When high temperature (heated by 5.0V), it detects Methane, Propane etc combustible gas and cleans the other gases adsorbed under low temperature. Please use simple electrocircuit, Convert change of conductivity to correspond output signal of gas concentration.

MQ-9 gas sensor has high sensitity to Carbon Monoxide, Methane and LPG. The sensor could be used to detect different gases contains CO and combustible gases, it is with low cost and suitable for different application.


Character:
  • Good sensitivity to CO/Combustible gas
  • High sensitivity to Methane, Propane and CO
  • Long life and low cost
  • Simple drive circuit

Application:
  • Domestic gas leakage detector
  • Industrial gas detector
  • Portable gas detector


Model No.
MQ-9
Sensor Type
Semiconductor
Standard Encapsulation
Bakelite
Detection Gas
CO and combustible gas
Concentration
10-1000ppm CO
100-10000ppm combustible gas
Circuit
Loop Voltage
Vc
≤10V DC
Heater Voltage
VH
 5.0V±0.2V AcorDC(High)
1.5V±0.1V ACorDC(Low)
Heater Time
TL
60±1S(High)90±1S(Low)
Load Resistance
RL
Adjustable
Character
Heater Resistance
RH
31Ω±3Ω(Room Tem.)
Heater consumption
PH
≤350mW
Sensing Resistance
Rs
2KΩ-20KΩ(in 100ppm CO)
Sensitivity
S
Rs(in air)/Rs(100ppm CO)≥5
Slope
      α
≤0.6(R300ppm/R100ppm CO)
 Condition           Tem. Humidity
20℃±2℃; 65%±5%RH
Standard test circuit
            Vc:5.0V±0.1V;
            VH(High): 5.0V±0.1V;
            VH(Low): 1.5V±0.1V
Preheat time
Over 48 hours

MQ-8 hydrogen gas sensor semiconductors.

MQ-8 hydrogen gas sensor semiconductors.

Sensitive material MQ-8 gas sensor is used in clean air low conductivity tin oxide (SnO2).When the sensor is exposed in the presence of hydrogen, conductivity sensor with increasing concentration of combustible gases in air increases. Using a simple circuit to convert the change in conductivity of the gas concentration corresponding to the output signal. 



MQ-8 hydrogen gas sensor of high sensitivity, the monitoring of the other hydrogen-containing gas is also very satisfactory. This sensor can detect a wide range of hydrogen gas, city gas in particular, is a low-cost sensor for a variety of applications.


Feature 

  • In a wide range of concentrations with good sensitivity to hydrogen 
  • Long-life, low cost 
  • Simple drive circuit can be



Technical indicators
Model
MQ-8
Product Type
Semiconductor gas sensor
Standard package
Bakelite (black bakelite)
Detection of gas
Hydrogen
Detectable concentration
100-1000ppm (hydrogen)
Standard circuit conditions
Circuit voltage
c
≤ 24V DC
Heating voltage
H
5.0V ± 0.2V ACorDC
Load Resistance
L
Adjustable
Under standard test conditions sensing Characteristics
Heating resistor
H
31Ω ± 3Ω (room temperature)
Heating consumption
H
≤ 900mW
Sensing Resistance
s
2KΩ-20KΩ (in 1000ppm H 2)
Sensitivity
S
Rs (in air) / Rs (1000ppm hydrogen) ≥ 5
Concentration gradient
α
≤ 0.6 (R 5000ppm / R3000ppm CH 4)
Standard Test Conditions
Temperature, humidity
20 ℃ ± 2 ℃; 65% ± 5% RH
Standard Test Circuit
Vc: 5.0V ± 0.1V;
H: 5.0V ± 0.1V
Warm-up time
Less than 48 hours

MQ-2 Semiconductor Gas Sensor

MQ-2 Semiconductor Gas Sensor
Sensitive material of MQ-2 gas sensor is SnO2, which with lower conductivity in clean air. When the target combustible gas exist, The sensor's conductivity is more higher along with the gas concentration rising. Please use simple electrocircuit, Convert change of conductivity to correspond output signal of gas concentration.

MQ-2 gas sensor has high sensitity to LPG, Propane and Hydrogen, also could be used to Methane and other combustible steam, it is with low cost and suitable for different application.


Character:
  • Good sensitivity to Combustible gas in wide range
  • High sensitivity to LPG, Propane and Hydrogen
  • Long life and low cost
  • Simple drive circuit

Application:
  • Domestic gas leakage detector
  • Industrial combustible gas detector
  • Portable gas detector


Technical Parameters:
Model No.
MQ-2
Sensor Type
Semiconductor
Standard Encapsulation
Bakelite (Black Bakelite)
Detection Gas
Combustible gas and smoke
Concentration
300-10000ppm
( Combustible gas)
Circuit
Loop Voltage
Vc
≤24V  DC
Heater Voltage
VH
5.0V±0.2V ACorDC
Load Resistance
RL
Adjustable
Character
Heater Resistance
RH
31Ω±3Ω(Room Tem.)
Heater consumption
PH
≤900mW
Sensing Resistance
Rs
2KΩ-20KΩ(in 2000ppm C3H8 )
Sensitivity
S
Rs(in air)/Rs(1000ppm isobutane)≥5
Slope
α
≤0.6(R5000ppm/R3000ppm CH4)
Condition
Tem.  Humidity
20℃±2℃;65%±5%RH
Standard test circuit
Vc:5.0V±0.1V;
          VH: 5.0V±0.1V
Preheat time
Over 48 hours

MQ135 Semiconductor Sensor for Air Quality.

Sensitive material of MQ135 gas sensor is SnO2, which with lower conductivity in clean air. When the target combustible gas exist, The sensor’s conductivity is more higher along with the gas concentration rising. Please use simple electrocircuit, Convert change of conductivity to correspond output signal of gas concentration.

MQ135 gas sensor has high sensitity to Ammonia, Sulfide and Benze steam, also sensitive to smoke and other harmful gases. It is with low cost and suitable for different application.


Character:
  • Good sensitivity to Harmful gases in wide range
  • High sensitivity to Ammonia, Sulfide and Benze
  • Long life and low cost
  • Simple drive circuit

Application:
  • Domestic air pollution detector
  • Industrial air pollution detector
  • Portable air pollution detector


Technical Paremeters:
Model No.
MQ135
Sensor Type
Semiconductor
Standard Encapsulation
Bakelite (Black Bakelite)
Detection Gas
Ammonia, Sulfide, Benze steam
Concentration
10-10000ppm
(Ammonia, Benze, Hydrogen)
Circuit
Loop Voltage
Vc
≤24V  DC
Heater Voltage
VH
5.0V±0.2V AC or DC
Load Resistance
RL
Adjustable
Character
Heater Resistance
RH
31Ω±3Ω(Room Tem.)
Heater consumption
PH
≤900mW
Sensing Resistance
Rs
2KΩ-20KΩ(in 100ppm NH3 )
Sensitivity
S
Rs(in air)/Rs(100ppm NH3)≥5
Slope
     α
≤0.6(R100ppm/R50ppm NH3)
Condition
Tem.  Humidity
20℃±2℃;65%±5%RH
Standard test circuit
Vc:5.0V±0.1V;
                   VH: 5.0V±0.1V
Preheat time
Over 48 hours

Figaro TGS3830 Industrial safety

Figaro TGS3830 Industrial safety



Features:
* Low power consumption
* High sensitivity to R-134a
* Quick response to R-134a

Application example: 
Portable refrigerant leak detector







Specifications:
Target gasesHalocarbon gas
Typical detection range5-100ppm
Sensing principleMOS type
Driving voltagesHeater Voltage:0.8V±3%
Circuit Voltage:5.0V
Power consumptionapprox. 100mW
Dimensionsφ9.2×8.5mm
WeightApprox. 1.1g

Saturday, April 26, 2014

Gas Sensor Sampler Kit

Gas Sensor Sampler Kit is a collection of some of the gas sensor module that can be used with Parallax microcontrollers. Gas Sensor Sampler kit is suitable for gas identification, monitoring gas levels, and other applications associated with the gas. 

specifications: 
- 1pcs CO Gas Sensor Module (MQ-7
- 1pcs CO2 Gas Sensor Module (MG-811) 
- 2pcs LPG Gas Sensor Module (MQ-5
- Bonus 4 pcs of screw drives

Monday, June 10, 2013

Lutron DO-5510 DISSOLVED OXYGEN METER with RS-232 interface



Lutron DO-5510 DISSOLVED OXYGEN METER with RS-232 interface


Technical Specs:
* Model : DO-5510
* -P circuit, LCD with display unit.
* Dissolved oxygen range : 0 to 20 mg/L.
* Max., Min., Memory recall button.
* DO, Oxygen in air, Temp., ATC, Auto Cal., % salt.
* Diaphragms & electrolyte included.
* Probe head with diaphragm set and electrolyte are included.
* Size : 180 x 72 x 32 mm. RS-232.


Lutron DO-5509 pocket size DISSOLVED OXYGEN METER

Lutron DO-5509 pocket size DISSOLVED OXYGEN METER



Technical Specs:
* Model : DO-5509 
* Range : 0 to 20 mg/L.
* ATC. Resolution : 0.1 mg/L.
* Pocket size, 13 mm LCD.
* Size : 131 x 70 x 25 mm.

Thursday, April 25, 2013

Vernier Dissolved Oxygen Probe

Use the Dissolved Oxygen Probe to determine the concentration of oxygen in aqueous solutions in the field or in the laboratory.

The Dissolved Oxygen Probe is great for biology, chemistry, ecology, or integrated science courses. It can be used to perform a wide variety of experiments to determine changes in dissolved oxygen levels, one of the primary indicators of the quality of an aquatic environment.
Built-in temperature compensation lets you calibrate in the lab, then make measurements outdoors without having to recalibrate.
Disposable caps with pre-fit membranes allow you to quickly and conveniently change membranes.
Calibrate in the units you choose: % dissolved oxygen, mg/L, or ppm dissolved oxygen

Specifications
  • Range: 0 to 15 mg/L (or ppm)
  • Accuracy: ±0.2 mg/L
  • Response Time: 95% of final reading in 30 seconds, 98% in 45 seconds
  • Resolution: 0.014 mg/L (LabQuest 2, LabQuest, LabQuest Mini, Go!Link, LabPro)
  • Temperature Compensation: automatic from 5–35°C
  • Pressure Compensation: manual
  • Salinity Compensation: manual
  • Minimum sample flow: 20 cm/second
What’s Included
  • Vernier Dissolved Oxygen Probe (dissolved oxygen electrode with membrane cap)
  • One replacement membrane cap
  • Sodium Sulfite Calibration Standard (2.0 M Na2SO3) and MSDS sheet
  • D.O. Electrode Filling Solution, MSDS sheet, and filling pipet
  • Calibration bottle (empty, lid with hole)
  • D.O. Polishing Strips (1 pkg)
  • User Manual
Sensor Requirements

The Dissolved Oxygen Probe requires a compatible interface and software to collect data. Interface and software sold separately

Compatible Interfaces

The Dissolved Oxygen Probe is compatible with these interfaces:
  • LabQuest 2
  • LabQuest
  • LabQuest Mini
  • Go!Link
  • SensorDAQ
  • NXT Sensor Adapter
  • LabPro
  • Vernier EasyLink
  • CBL 2
  • TI-Nspire Lab Cradle

Tuesday, April 23, 2013

SG-2008G smoke or LPG sensor

SG-2008G smoke or LPG sensor

Gas sensor module to detect smoke or LPG

specifications:
- Power supply: 12 VDC
- Detects smoke or LPG
- Have a sound as the alarm noise> 85db
- Integrated internal relay configuration with NO / NC
- The installation of the sensor module can be placed on the ceiling or wall