TGS2603 Air Quality / Odor sensor
TGS2603 is a gas sensor which is suitable for application in the automotive, appliance air controller, and a smart home. This tool can detect gas contamination trimethylamine, methyl mercaptan and gases - other gases to the air we breathe.
specifications:
- Target gas: Trimethylamine, methyl mercaptan, and others - others
- The detection range: 1 - 10ppm EtOH
- The principle of sensing: MOS Type
- Heating Voltage: 5 V
- Circuit voltage: 5 V
- Power consumption: 20 mW
- Dimensions: 9.2 × 7.8mm
- Weight: 1 gr
- Features: Low power consumption, sensitivity tinngi against sulfur gas, using a simple electric circuit
Monday, January 25, 2016
MiCS-2714 NO2 MOS gas sensor
MICS 2714 this is a sensitive sensor to detect the levels of Nitrogen Dioxide (NO2) and hydrogen (H2).
With SMD packaging shapes, make us easy to use in projects that require small size.
This sensor can also be used to detect gas leaks.
Features:
- Size: 5 x 7 x 1.55 (mm).
- Suitable for the neighborhood / area factories / industries.
Saturday, October 03, 2015
TGS832-A00 Halocarbons gas sensor by Figaro
TGS832-A00 Halocarbons gas sensor by Figaro
Features
* High sensitivity to refrigerant gases
* Quick response
* Long term stability
* Uses simple electrical circuit
* Quick response
* Long term stability
* Uses simple electrical circuit
Application examples
* Portable and fixed installation refrigerant leak detectors
Specifications
Target gases | Halocarbon gas |
---|---|
Typical detection range | 10 - 1,000ppm |
Sensing principle | MOS type |
Driving voltage | Heater Voltage:5.0V Circuit Voltage:Max24V |
Power consumption | 835mW |
Dimensions | φ17×10mm |
Weight | Approx. 2.4g |
Saturday, July 11, 2015
Wednesday, January 21, 2015
M201 Air Quality Module
M201 adopts semi-conductor gas sensor and high performance MPU. It has Uart and I2C digital output and open set switch output. The module is applied to the development of the equipment for air quality detecting and controlling.
Application:
Air purifier, air pollution monitor, automatic vent device
Specification:
- Target gas :Hydrogen
- Detection range :20-150ppm
- Sensor type :Semi-conductor
- Response time :< 30s
- Recovery time :< 50s
- Working voltage :2.8-5.0V
- Working current :< 120 mA
- Output :Uart: Baud Rate 4800,n,8,1
- Product Capability :<15 li="" ppm="">
- Precision :+/-15%(80ppm)
- Expected lifespan :>2 years
- Working condition :Temperature:0-55 C
- Humidity:20%-90%RH
- Storage condition :Temperature:-20-70 C
- Humidity:20%-90%RH
- External dimensions :25X24X18mm(LXWXH) 15>
Tuesday, April 29, 2014
Low Cost Electronic modules Gas Sensor
There are several low cost Electronic modules for gas Sensor:
more Sensor , Gas sensor, and Electronic Modules
- Low Cost Carbon Monooxide sensor module
- Low Cost CO2 sensor module
- Low Cost Alcohol sensor module
- Low Cost methane gas sensor module
- Low Cost LPG sensor module
- Low Cost Air Quality Sensor module
more Sensor , Gas sensor, and Electronic Modules
MG811 Carbon Dioxide Sensor
MG811 Carbon Dioxide Sensor
Features:
- Good sensitivity and selectivity to CO2
- Low humidity and temperature dependency
- Long stability and reproducibility
Application:
- Air Quality Control
- Ferment Process Control
- Room temperature CO2 concentration detection
Technical Parameters:
Symbol
|
Parameter Name
|
Technical
|
Remarks
|
VH
|
Heating Voltage
|
6.0±0.1 V
|
AC or DC
|
RH
|
Heating Resistor
|
30.0±5% Ω
|
Room Temperature
|
IH
|
Heating Current
|
200mA
| |
PH
|
Heating Power
|
1200mW
| |
Tao
|
Operating
|
-20—50℃
| |
Tas
|
Temperature
|
-20—70℃
| |
∆ E M F
|
Storage Temperature
|
30—50mV
|
350—10000ppmCO2
|
MQ-9 Semiconductor Sensor for CO/Combustible Gas.
MQ-9 Semiconductor Sensor for CO/Combustible Gas
Sensitive material of MQ-9 gas sensor is SnO2, which with lower conductivity in clean air. It make detection by method of cycle high and low temperature, and detect CO when low temperature (heated by 1.5V). The sensor’s conductivity is more higher along with the gas concentration rising. When high temperature (heated by 5.0V), it detects Methane, Propane etc combustible gas and cleans the other gases adsorbed under low temperature. Please use simple electrocircuit, Convert change of conductivity to correspond output signal of gas concentration.
MQ-9 gas sensor has high sensitity to Carbon Monoxide, Methane and LPG. The sensor could be used to detect different gases contains CO and combustible gases, it is with low cost and suitable for different application.
Character:
- Good sensitivity to CO/Combustible gas
- High sensitivity to Methane, Propane and CO
- Long life and low cost
- Simple drive circuit
Application:
- Domestic gas leakage detector
- Industrial gas detector
- Portable gas detector
Model No.
|
MQ-9
| ||
Sensor Type
|
Semiconductor
| ||
Standard Encapsulation
|
Bakelite
| ||
Detection Gas
|
CO and combustible gas
| ||
Concentration
|
10-1000ppm CO
100-10000ppm combustible gas
| ||
Circuit
|
Loop Voltage
|
Vc
|
≤10V DC
|
Heater Voltage
|
VH
|
5.0V±0.2V AcorDC(High)
1.5V±0.1V ACorDC(Low)
| |
Heater Time
|
TL
|
60±1S(High)90±1S(Low)
| |
Load Resistance
|
RL
|
Adjustable
| |
Character
|
Heater Resistance
|
RH
|
31Ω±3Ω(Room Tem.)
|
Heater consumption
|
PH
|
≤350mW
| |
Sensing Resistance
|
Rs
|
2KΩ-20KΩ(in 100ppm CO)
| |
Sensitivity
|
S
|
Rs(in air)/Rs(100ppm CO)≥5
| |
Slope
| α |
≤0.6(R300ppm/R100ppm CO)
| |
Condition | Tem. Humidity |
20℃±2℃; 65%±5%RH
| |
Standard test circuit
|
Vc:5.0V±0.1V;
VH(High): 5.0V±0.1V;
VH(Low): 1.5V±0.1V
| ||
Preheat time
|
Over 48 hours
|
MQ-8 hydrogen gas sensor semiconductors.
MQ-8 hydrogen gas sensor semiconductors.
Feature
Sensitive material MQ-8 gas sensor is used in clean air low conductivity tin oxide (SnO2).When the sensor is exposed in the presence of hydrogen, conductivity sensor with increasing concentration of combustible gases in air increases. Using a simple circuit to convert the change in conductivity of the gas concentration corresponding to the output signal.
MQ-8 hydrogen gas sensor of high sensitivity, the monitoring of the other hydrogen-containing gas is also very satisfactory. This sensor can detect a wide range of hydrogen gas, city gas in particular, is a low-cost sensor for a variety of applications.
- In a wide range of concentrations with good sensitivity to hydrogen
- Long-life, low cost
- Simple drive circuit can be
Technical indicators
Model
|
MQ-8
| ||
Product Type
|
Semiconductor gas sensor
| ||
Standard package
|
Bakelite (black bakelite)
| ||
Detection of gas
|
Hydrogen
| ||
Detectable concentration
|
100-1000ppm (hydrogen)
| ||
Standard circuit conditions
|
Circuit voltage
|
V c
|
≤ 24V DC
|
Heating voltage
|
V H
|
5.0V ± 0.2V ACorDC
| |
Load Resistance
|
R L
|
Adjustable
| |
Under standard test conditions sensing Characteristics
|
Heating resistor
|
R H
|
31Ω ± 3Ω (room temperature)
|
Heating consumption
|
P H
|
≤ 900mW
| |
Sensing Resistance
|
R s
|
2KΩ-20KΩ (in 1000ppm H 2)
| |
Sensitivity
|
S
|
Rs (in air) / Rs (1000ppm hydrogen) ≥ 5
| |
Concentration gradient
| α |
≤ 0.6 (R 5000ppm / R3000ppm CH 4)
| |
Standard Test Conditions
|
Temperature, humidity
|
20 ℃ ± 2 ℃; 65% ± 5% RH
| |
Standard Test Circuit
|
Vc: 5.0V ± 0.1V;
V H: 5.0V ± 0.1V
| ||
Warm-up time
|
Less than 48 hours
|
MQ-2 Semiconductor Gas Sensor
MQ-2 Semiconductor Gas Sensor
Sensitive material of MQ-2 gas sensor is SnO2, which with lower conductivity in clean air. When the target combustible gas exist, The sensor's conductivity is more higher along with the gas concentration rising. Please use simple electrocircuit, Convert change of conductivity to correspond output signal of gas concentration.
MQ-2 gas sensor has high sensitity to LPG, Propane and Hydrogen, also could be used to Methane and other combustible steam, it is with low cost and suitable for different application.
Character:
- Good sensitivity to Combustible gas in wide range
- High sensitivity to LPG, Propane and Hydrogen
- Long life and low cost
- Simple drive circuit
Application:
- Domestic gas leakage detector
- Industrial combustible gas detector
- Portable gas detector
Technical Parameters:
Model No.
|
MQ-2
| ||
Sensor Type
|
Semiconductor
| ||
Standard Encapsulation
|
Bakelite (Black Bakelite)
| ||
Detection Gas
|
Combustible gas and smoke
| ||
Concentration
|
300-10000ppm
( Combustible gas) | ||
Circuit
|
Loop Voltage
|
Vc
|
≤24V DC
|
Heater Voltage
|
VH
|
5.0V±0.2V ACorDC
| |
Load Resistance
|
RL
|
Adjustable
| |
Character
|
Heater Resistance
|
RH
|
31Ω±3Ω(Room Tem.)
|
Heater consumption
|
PH
|
≤900mW
| |
Sensing Resistance
|
Rs
|
2KΩ-20KΩ(in 2000ppm C3H8 )
| |
Sensitivity
|
S
|
Rs(in air)/Rs(1000ppm isobutane)≥5
| |
Slope
| α |
≤0.6(R5000ppm/R3000ppm CH4)
| |
Condition
|
Tem. Humidity
|
20℃±2℃;65%±5%RH
| |
Standard test circuit
|
Vc:5.0V±0.1V;
VH: 5.0V±0.1V
| ||
Preheat time
|
Over 48 hours
|
MQ135 Semiconductor Sensor for Air Quality.
Sensitive material of MQ135 gas sensor is SnO2, which with lower conductivity in clean air. When the target combustible gas exist, The sensor’s conductivity is more higher along with the gas concentration rising. Please use simple electrocircuit, Convert change of conductivity to correspond output signal of gas concentration.
MQ135 gas sensor has high sensitity to Ammonia, Sulfide and Benze steam, also sensitive to smoke and other harmful gases. It is with low cost and suitable for different application.
Character:
- Good sensitivity to Harmful gases in wide range
- High sensitivity to Ammonia, Sulfide and Benze
- Long life and low cost
- Simple drive circuit
Application:
- Domestic air pollution detector
- Industrial air pollution detector
- Portable air pollution detector
Technical Paremeters:
Model No.
|
MQ135
| ||
Sensor Type
|
Semiconductor
| ||
Standard Encapsulation
|
Bakelite (Black Bakelite)
| ||
Detection Gas
|
Ammonia, Sulfide, Benze steam
| ||
Concentration
|
10-10000ppm
(Ammonia, Benze, Hydrogen) | ||
Circuit
|
Loop Voltage
|
Vc
|
≤24V DC
|
Heater Voltage
|
VH
|
5.0V±0.2V AC or DC
| |
Load Resistance
|
RL
|
Adjustable
| |
Character
|
Heater Resistance
|
RH
|
31Ω±3Ω(Room Tem.)
|
Heater consumption
|
PH
|
≤900mW
| |
Sensing Resistance
|
Rs
|
2KΩ-20KΩ(in 100ppm NH3 )
| |
Sensitivity
|
S
|
Rs(in air)/Rs(100ppm NH3)≥5
| |
Slope
| α |
≤0.6(R100ppm/R50ppm NH3)
| |
Condition |
Tem. Humidity
|
20℃±2℃;65%±5%RH
| |
Standard test circuit
|
Vc:5.0V±0.1V;
VH: 5.0V±0.1V
| ||
Preheat time
|
Over 48 hours
|
Figaro TGS3830 Industrial safety
Figaro TGS3830 Industrial safety
Features:
* Low power consumption
* High sensitivity to R-134a
* Quick response to R-134a
Application example:
Portable refrigerant leak detector
Specifications:
Features:
* Low power consumption
* High sensitivity to R-134a
* Quick response to R-134a
Application example:
Portable refrigerant leak detector
Specifications:
Target gases | Halocarbon gas |
---|---|
Typical detection range | 5-100ppm |
Sensing principle | MOS type |
Driving voltages | Heater Voltage:0.8V±3% Circuit Voltage:5.0V |
Power consumption | approx. 100mW |
Dimensions | φ9.2×8.5mm |
Weight | Approx. 1.1g |
Saturday, April 26, 2014
Gas Sensor Sampler Kit
Gas Sensor Sampler Kit is a collection of some of the gas sensor module that can be used with Parallax microcontrollers. Gas Sensor Sampler kit is suitable for gas identification, monitoring gas levels, and other applications associated with the gas.
specifications:
- 1pcs CO Gas Sensor Module (MQ-7)
- 1pcs CO2 Gas Sensor Module (MG-811)
- 2pcs LPG Gas Sensor Module (MQ-5)
- Bonus 4 pcs of screw drives
Monday, June 10, 2013
Lutron DO-5510 DISSOLVED OXYGEN METER with RS-232 interface
Lutron DO-5510 DISSOLVED OXYGEN METER with RS-232 interface
* Model : DO-5510
* -P circuit, LCD with display unit.
* Dissolved oxygen range : 0 to 20 mg/L.
* Max., Min., Memory recall button.
* DO, Oxygen in air, Temp., ATC, Auto Cal., % salt.
* Diaphragms & electrolyte included.
* Probe head with diaphragm set and electrolyte are included.
* Size : 180 x 72 x 32 mm. RS-232.
Thursday, April 25, 2013
Vernier Dissolved Oxygen Probe
Use the Dissolved Oxygen Probe to determine the concentration of oxygen in aqueous solutions in the field or in the laboratory.
The Dissolved Oxygen Probe is great for biology, chemistry, ecology, or integrated science courses. It can be used to perform a wide variety of experiments to determine changes in dissolved oxygen levels, one of the primary indicators of the quality of an aquatic environment.
Built-in temperature compensation lets you calibrate in the lab, then make measurements outdoors without having to recalibrate.
Disposable caps with pre-fit membranes allow you to quickly and conveniently change membranes.
Calibrate in the units you choose: % dissolved oxygen, mg/L, or ppm dissolved oxygen
Specifications
- Range: 0 to 15 mg/L (or ppm)
- Accuracy: ±0.2 mg/L
- Response Time: 95% of final reading in 30 seconds, 98% in 45 seconds
- Resolution: 0.014 mg/L (LabQuest 2, LabQuest, LabQuest Mini, Go!Link, LabPro)
- Temperature Compensation: automatic from 5–35°C
- Pressure Compensation: manual
- Salinity Compensation: manual
- Minimum sample flow: 20 cm/second
What’s Included
- Vernier Dissolved Oxygen Probe (dissolved oxygen electrode with membrane cap)
- One replacement membrane cap
- Sodium Sulfite Calibration Standard (2.0 M Na2SO3) and MSDS sheet
- D.O. Electrode Filling Solution, MSDS sheet, and filling pipet
- Calibration bottle (empty, lid with hole)
- D.O. Polishing Strips (1 pkg)
- User Manual
Sensor Requirements
The Dissolved Oxygen Probe requires a compatible interface and software to collect data. Interface and software sold separately
Compatible Interfaces
The Dissolved Oxygen Probe is compatible with these interfaces:
- LabQuest 2
- LabQuest
- LabQuest Mini
- Go!Link
- SensorDAQ
- NXT Sensor Adapter
- LabPro
- Vernier EasyLink
- CBL 2
- TI-Nspire Lab Cradle
Tuesday, April 23, 2013
SG-2008G smoke or LPG sensor
SG-2008G smoke or LPG sensor
Gas sensor module to detect smoke or LPG
specifications:
- Power supply: 12 VDC
- Detects smoke or LPG
- Have a sound as the alarm noise> 85db
- Integrated internal relay configuration with NO / NC
- The installation of the sensor module can be placed on the ceiling or wall
Gas sensor module to detect smoke or LPG
specifications:
- Power supply: 12 VDC
- Detects smoke or LPG
- Have a sound as the alarm noise> 85db
- Integrated internal relay configuration with NO / NC
- The installation of the sensor module can be placed on the ceiling or wall