Friday, March 28, 2014

Mastech MS2302 Digital Earth Resistance Tester

Mastech MS2302 Digital Earth Resistance Tester

Features:

  • Large LCD display with bar graph
  • 2 Pole/ 3Pole Measurement Modes
  • Earth resistance measured by constant current inverter 800Hz/3mA
  • MAX/MIN/AVG/REL Measurement Functions
  • Data Logging up to 100 groups
  • Measures Voltage to Earth
  • Display back light
 Specification:

Digital Display & Analog Bars Display
2 Pole and 3 Pole Mode
Earth resistance by constant current inverter 800Hz/3mA
MAX/MIN/AVG/REL Measurement Functions
Data Logging : 100 group measured values can be memorized
Low Battery Display
Display Backlight
Description
Measuring Range
Accuracy
Resolution
Earth Ground Resistance
0Ω~29.99Ω
±(1%+2)
0.01Ω
30Ω~99.9Ω
±(3%+2)
0.1Ω
100Ω~999Ω
±(3%+2)
1Ω
1.00kΩ~4.00kΩ
±(3%+2)
10Ω
Measuring Voltage
0V~20.0V (50~60Hz)
±(1%+5)
0.1V



Mastech MS2208 Single Phase Harmonic Power Meter

Mastech  MS2208 Single Phase Harmonic Power Meter


Features:
  • Large Dual 6000 Counts LCD Display
  • Measures AC Voltage, AC Current, Single Phase Active Power, Power Factor, Passive Power, Frequency and Harmonic
  • Data Hold and Display Back Light
  • Auto Power Off


Specification
Range
Accuracy
AC Voltage(TRMS)
10V ~ 600V
±(1%+5)
AC Current(TRMS)
2mA ~ 3999mA
±(2%+5)
4A ~ 200A
±(2%+5)
Single phase active power(kW)
0.1W ~ 120KW
±(3%+5)
Single phase apparent power(kVA)
0.01kVA ~ 120kVA
±(3%+5)
Single phase reactive power(kVAr)
0.01kVAr ~ 120kVAr
±(3%+5)
Power Factor
0.3~1 capacitive
±(2%+2)
0.3~1 inductive
±(2%+2)
Frequency(Hz)
30Hz~1kHz
±(0.5%+1)
Harmonic measurement
Harmonic number: 1
±(3.0%+10)
Harmonic number: 2~6
±(3.5%+10)
Harmonic number: 7~8
±(4.5%+10)
Harmonic number: 9~10
±(5.0%+10)
Harmonic number: 11~15
±(7.0%+10)
Harmonic number: 16~20
±(10%+10)
Display
6000 counts
Jaw Opening
Φ26mm/1.0”
Auto Ranging
√
MAX/MIN
MAX/MIN measurement mode
Flash Light
Pointing to the target area
Data Hold
√
Display   Backlight
√

Mastech MS2203 Three Phase Digital Power Clamp Meter

Mastech MS2203 Three Phase Digital Power Clamp Meter


Features
  • Power measurement of 3-phase 3-wire, 3-phase 4-wire, single-phase mode
  • V, A, W, VA, VAR, kWh, PF, Hz measurement
  • Double display two parameters on each menu and store 28 groups of measurement parameter
  • Measure total power value and five power parameters of each phase in 3-phase measurement mode respectively
  • Autorange and TRMS display
  • With PC RS232 interface and windows graphics software
  • Display measurement time and select tested signal be power supply for the clamp at one time, the instrument can measurement for long time
  • Large LCD display, multifunctional button control
Specifications:
  • Max conductor size Φ50mm
  • AC Current(A) 40/100/400/1000A±2%
  • AC Voltage(V) 100/300/600V±1.2%
  • Active Power(kW) 4/10/40/100/600kW±3.0%
  • Apparent Power(kVA) 4/10/40/100/600kVA±3.0%
  • Power Factor(PF) 0.3cap to 0.3ind±0.02
  • Reactive Power(KVAR) 4/10/40/100/600kVAR±4.0%
  • Active Energy(kWh) 10/100/1000/10000kWh±3.0%
  • Frequency(Hz) 20Hz~ 1000Hz 0.5%
  • Display 4 digits LCD 9999
  • Power supply 4 x 1.5V AA
  • Operating Temperature 0°C~ 40°C
  • Dimensions 300mmx 103mm x 51mm
  • Weight Approx. 500g

Monday, March 24, 2014

Atmel AT89LV55-12PC microcontroller

Atmel AT89LV55-12PC microcontroller
8-bit microcontroller  MCS-51 family

specifications: 
- Architecture: 8051
- Working voltage: 2.7V - 6V DC
- Program memory size: 20KB
- Volatile data memory size: 256 Bytes
- The size of non-volatile data memory: -
- Peripherals: I / O ports, UART
- Number of I / O: 32
- Number of external interrupts: 8
- Timer / Counter: Three 16-bit Timer / Counter
- Working frequency: 0Hz - 12MHz
- Programming interface: Parallel (non-ISP)
- Interface peripherals: UART
- Special Features: Low Power Idle and Power Down Modes, Three-level Program Memory Lock.
- Packaging: PDIP-40

Tuesday, March 18, 2014

MS2138R DIGITAL AC/DC CLAMP METER

MS2138R DIGITAL AC/DC CLAMP METER

Features:
  • Big Jaw Size up to Φ40mm/1.6” 
  • 4000 Counts Digital LCD Display 
  • Measures AC/DC Current up to 1000A 
  • Work Light and Back Light 
  • True RMS for AC Current and Voltage 
  • Tests AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency and Duty Cycle 
  • Diode Check and Continuity Test 
  • MAX/MIN, Data Hold and Auto Power Off 

Display
counts
4000
Jaw Opening

Φ40mm/1.6”
Auto Ranging

√
Manual Ranging

√
Auto Power Off

√
Diode
2.7V
√
Continuity Buzzer
<50 p="">
√
REL
Relative measurement
√

Specifications:
DC Voltage
400mV/4V/40V/400V
±(0.7% +3)
600V
±(0.8% +2)
AC Voltage
4V/40V/400V
±(0.8% +3)
600V
±(1% +4)
AC Current
40A/400A/1000A
±(2.5% +6)
DC Current
40A/400A/1000A
±(3.0% +6)
Resistance
400Ω/4kΩ/40kΩ/400kΩ/4MΩ
±(0.8% +3)
40MΩ
±(1.2% +3)
Capacitance
40nF/400nF/4µF/40µF/400µF/4000µF
±(4.0% +5)
Frequency (From Clamp)
0~ 1KHz
±(1.5% +5)
Frequency (From Plug)
0~10MHz
±(0.5% +3)
Duty Cycle
10%~ 90%
±3.0%

MS2108A DIGITAL AC/DC CLAMP METER

MS2108A DIGITAL AC/DC CLAMP METER



Features:
  • Jaw Size: Φ26mm/1.0”
  • Tests AC/DC Voltage and Current, Resistance, Capacitance, Frequency and Duty Cycle
  • Work Light and Display Back Light
  • Diode Check and Continuity Test
  • MAX/MIN and Data Hold


Display
counts
4000
Jaw Opening

Φ26mm/1.0”
Auto Ranging

√
Manual Ranging


Auto Power Off

√
Inrush
Integration Time: 100ms

True RMS
True Root Mean Square Measurement

REL
Relative measurement
√
Diode
2.7V
√
Continuity Buzzer
<50 p="">
√
MAX/MIN

√
Data Hold

√
Low Battery Display

√
Display Backlight

√
Flash Light

√

Specifications:
DC Voltage
660mV/6.6V

66V/600V

400mV/4V
±(0.8% +3)
40V/400V/1000V
±(1.0% +5)
AC Voltage
660mV

6.6V/66V

600V

4V/40V/400V
±(0.8% +3)
750V
±(1.0% +5)
DC Current
66A/600A

40A/400A
±(2.0% +6)
AC Current
66A/600A

40A/400A
±(2.0% +6)
Inrush Current (100ms)
66A/600A

Resistance
660Ω/6.6kΩ/66kΩ/660kΩ/6.6MΩ

66MΩ

400Ω/4kΩ/40kΩ/400KΩ
±(0.8% +3)
4MΩ/40MΩ
±(1.2% +3)
Capacitance
6.6µF/66µF/660µF/6.6mF/66mF

400nF/4µF/40µF/400µF/4000µF
±(4.0% +5)
Frequency (From Clamp)
0~ 1KHz

0~ 10KHz
±(1.5% +5)
Frequency (From Plug)
0~ 10KHz

0~ 10MHz
±(1.5% +5)
Duty Cycle
10%~ 90%
±3.0%