Monday, May 05, 2014

USB-RLY02 - 2 relay outputs at 16A.

USB-RLY02 - 2 relay outputs at 16A.

The USB-RLY02 provides two volt free contact relay outputs with a current rating of up to 16Amp each. The USB-RLY02 is powered and instructed from any standard USB bus and does not require any additional power. The relays are SPCO (Single Pole Change Over) types. The normally open, normally closed and common pins are all available on the screw terminals.

Operating Temperature
-40C to +70C
LED indicationThe USB-RLY02 provides a red LED mounted immediately next to each relay to indicate whether it is in a powered state (LED on).

Relay power rating
If the contact load voltage and current of the relay are in the region below the solid line in the
 figure below, the relay can perform stable switching operation. If the relay is used at a voltage or current exceeding this region, the life of the contacts may be significantly shortened.

 load type  Typical applications  Rating Max DC load capacity
 AC1 Non inductive or
 slightly inductive loads 
 16A @ 250V AC 
 AC15 Control of
 electromagnetic load
 (>72VA)
 3A @ 120V AC
 1.5A @ 240V AC 
 AC3 Control of motor  750W
 DC1 Non inductive or
 slightly inductive loads
 16A @ 24V DC 
 DC13 Control of electromagnetic
 loads
 0.22A @ 120V DC
 0.1A @ 250V DC