Thursday, May 22, 2014

Fluke 789 ProcessMeter™

Fluke 789 ProcessMeter™
Now compatible with Fluke Connect™ App


The Fluke 789 ProcessMeter is the ultimate troubleshooting tool for electricians and instrumentation professionals, combining the functionality of a loop calibrator with the power of a digital multimeter. By equipping the 789 with a temperature measurement module and the wireless data logging capabilities of Fluke Connect™ with ShareLive™ video call (sold separately), process technicians can now do a lot more while carrying a lot less. And with its built-in, selectable 250 ohm HART® resistor, it eliminates the need to carry a separate resistor with you.

Model NameDescription
Fluke 789Fluke 789 ProcessMeter™ 
Includes:

  • Fluke 789 ProcessMeter
  • AC175 Alligator Clips
  • Four (4) AA 1.5 V alkaline batteries (installed)
  • TL71 safety-designed test lead set

Features of the Fluke 789:
  • 24 V Loop power supply
  • Very large dual display
  • Enhanced backlight with 2 brightness settings
  • 1200 ohm drive capability on mA source
  • HART mode setting with loop power and a built-in 250 ohm resistor
  • 0% and 100 % buttons to toggle between 4 and 20 mA sourcing for a quick span check
  • Externally accessible fuses for easy replacement
  • Infrared-port to process data in FlukeView Forms (V2.1) software

Fluke 789 features that are also included in the Fluke 787:
  • Precision 1000 V, 440 mA True-RMS digital multimeter
  • 0.1% dc voltage accuracy
  • 0.05% dc current accuracy
  • Frequency measurement to 20 kHz
  • Min/Max/Average/Hold/Relative modes
  • Diode Test and Continuity Beeper
  • Simultaneous mA and % of scale readout
  • 20 mA DC current source / loop calibrator / simulator
  • Manual Step (100%, 25%, Coarse, Fine) plus Auto Step and Auto Ramp
  • Externally accessible battery for easy battery changes

Safety conformance
Meets 1000 Volt EN61010-1 CAT III standards and 600 Volt EN61010-1 CAT IV standards.

Specifications
Current measurementRange0-1 A AC or DC
Resolution1 mA
Accuracy0.2% + 2 LSD (DC)
Range0-30 mA
Resolution0.001 mA
Accuracy0.05% + 2 lSD
Current sourcingRange0-20 mA or 4-20 mA
Resolution0.05% of span
Drive capability24 V Compliance or 1200 Ω @ 20 mA
FrequencyTo 19.999 kHz, 0.005% + 1 LSD
ContinuityBeeps for resistance < 100 Ω
Voltage measurementRange0-1000 V AC (true-rms) or DC
Resolution0.1 mV to 1.0 V
Accuracy0.1% Rdg + 1 LSD (VDC)
Resistance measurementTo 40 MΩ, 0.2% + 1 LSD
Diode test2.0 V shoes diode voltage drop
Display current and % of spanYes
Auto Step, Auto RampYes

Environmental Specifications
Operating temperature-20 ºC to 55 ºC
Storage temperature-40 ºC to 60 ºC
Humidity (without condensation)95% up to 30 ºC
75% up to 40 ºC
45% up to 50 ºC
35% up to 55 ºC
Temperature coefficient0.05 x (specified accuracy) per ºC (for temperatures < 18 ºC or > 28 ºC)

Safety Specifications
Electrical safetyDesigned in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No 1010.1-92
Overvoltage categoryIEC 1010-1 CAT III 1000 V
IEC 1010-1 CAT IV 600 V
Maximum voltage1000 V rms

Mechanical and General Specifications
Size50 x 100 x 203 mm (1.25" H x 3.41"W x 7.35" L)
Weight610 g (1.6 lbs)
Batteries4 AA alkaline batteries
Warranty3 years
Battery life140 hours typical (measurement), 10 hours typical (sourcing 20 mA)
Shock and vibrationRandom, 2 g, 5-500 Hz
1 meter drop test