PS-303D laboratory power supply 0-30V/0-3Amp
Specifications
1. Ambient working condition and dimensions
Power supply voltage: 110V/220V±10% 50/60Hz (switch transformation)
Working condition: Temperature: 00C to 400C
Relative humidity: >80% Storage condition: Temperature:-100C to 700C Relative humidity: <70% 2. Stabilized Voltage working position (1)The output voltage is between 0 and nominal value continuously adjustable
(2) Voltage stability Power stability:<0.01%+3mV Load stability :< 0.01%+3mV (Max. current <3A) Load stability :< 0.01%+5mV (Max. current >3A)
(3) Recovery time < 100μS (load-variant50%, min. load current 0.5A)
(4) Ripple & noise :< 0.5mVrms (5Hz-1MHz) (Max. current <3A) <1.0mVrms (5Hz-1MHz) (Max. current >3A)
(5) Temperature coefficient < 300PPM/0C
3. Stabilized current working position
(1)The output current is between 0 and nominal value continuously adjustable
(2)Current stability
Power stability:<0.2%+3mA
Load stability :< 0.2%+3mA
(3) Ripple & noise :< 3mA (rms)
Model:
PS-302D:0-30V/0-2A
PS-303D: 0-30V/0-3A
PS-305D:0-30V/0-5A