The Hantek PP-80 probe has been designed and calibrated for use on instruments having an input impedance of 1MΩ paralleled by 20pF. It can also be recalibrated for use on instruments having an input capacitance of 15 to 40pF.
The PP-80 has a slide swich for 1x & 10x attenuation and a cable length of 1.2 meters. This item includes 1 60 Mhz probe with accessories.
Electrical Characteristics | |
Temperature | -15°C to 70°C |
Attenuation | X1 & X10 |
Input Capacity |
X1: 85pF~115pF
X10: 18.5pF~22.5pF
|
Oscilloscope Input capacity | 15pF~40pF |
Input Resistance: |
X1: 1MΩ±2%
X10: 10MΩ±2%
|
Bandwidth |
X1: DC-6MHz
X10: DC-60MHz
|
Max input Voltage |
X1: <200v ac="" dc="" p="" peak="">
X10: <600v ac="" dc="" p="" peak="">600v>
200v> |
Physical Characteristics | |
Probe Body | 95mm |
Coaxial Cable | 1200mm |
Weight | 55g(max.) |
Kit Includes:
- 1 Probe Tip
- 1 Ground Lead
- 8 Marker Rings, 2 Red, 2 Green, 2 Black, 2 Yellow
- 1 Tip Locating Sleeve
- 1 Adjustment Tool