Xiaomi Water TDS Tester
Xiaomi TDS (Total Dissolved Solids) Pen Tester is used to measure the clarity / quality of the water, whether for consumption or not.
Therefore, this tool can measure the concentration in the water as heavy metals, organic material and water salinity to take into account the level of water purity.
This tool is very convenient to carry around because of the size of a pen.
Basic Interface Shield & Labsheet Arduino 2 book
A package for training / learning module consists of The Basic Interface Shield for Arduino and the book "Learning Arduino Microcontroller Interface Applications vol 2" to SMK majoring in Electronic Engineering or Electronics Engineering Industry.
As in the book are learning materials such as:
- Sending and receiving data via UART.
- Accessing the RAM in the RTC DS1307.
- Reading of the value of the acceleration in the X-axis MMA7455L sensor.
- and others.
Monday, April 04, 2016
Fluke 87V/E2 Industrial Electrician Combo Kit
This combo kit is built around the Fluke 87V, the most widely used industrial digital multimeter in the world, and includes special accessories to make you even more productive on the job. This kit will save over 15% compared with the individual price of all the accessories. Plus you'll be working with the most trusted tools in the world.
Features
Electrical safety
All inputs are protected to the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600 V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals
Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.
Unique function for accurate measurements of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals
Accurately measure the frequency (motor speed). Frequency measurement not affected by the ASDs carrier frequency
Measure AC current with an optional current clamp accessory
Compare reading from the 87V with the display on the ASD
Special shielding blocks high frequency, high-energy noise generated by large drive systems
Features
- Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment
- Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
- Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
- Large digit display with bright, two-level backlight makes the 87V significantly easier to read than older models
- True-rms ac voltage and current for accurate measurements on non linear signals
- Selectable filter for accurate voltage and frequency measurements on motor drives
- 0.05% DC accuracy
- 6000 counts, 3-3/4 digits
- 4-1/2 digit mode for precise measurements (20,000 counts)
- Measure up to 1000 V AC and DC
- Measure up to 10 A, 20 A for up to 30 seconds
- Built in thermometer lets you carry one less tool (TC probe included)
- Frequency to 200 kHz and % duty cycle
- Resistance, continuity and diode test
- 10,000 µF capacitance range for components and motor caps
- Min/Max-Average recording with Min/Max Alert to capture variations automatically
- Peak capture to record transients as fast as 250 µs
- Relative mode to remove test lead interference from low ohms measurements
- Auto and manual ranging for maximum flexibility
- Touch Hold to capture stable readings avoiding noisy signals
- Large display digits and two-level bright white backlight for increased visibility
- Analog bargraph for fast changing or unstable signals
- Input Alert provides audible warning against wrong use of input jacks
- Improved selectable sleep mode for long battery life
- Access door for fast battery changes without breaking the calibration seal
- "Classic" design with new removable holster with built in test lead and probe storage
Electrical safety
All inputs are protected to the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600 V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals
Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.
Unique function for accurate measurements of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals
Accurately measure the frequency (motor speed). Frequency measurement not affected by the ASDs carrier frequency
Measure AC current with an optional current clamp accessory
Compare reading from the 87V with the display on the ASD
Special shielding blocks high frequency, high-energy noise generated by large drive systems
Specifications Voltage DC Maximum Voltage 1000 V Accuracy ±(0.05% + 1) Maximum Resolution 10 µV Voltage AC Maximum Voltage 1000 V Accuracy ±(0.7% + 2) True RMS AC Bandwidth 20 kHz with low pass filter; 3 db @ 1 kHz Maximum Resolution 0.1 mV Current DC Maximum Amps 10 A (20 A for 30 seconds maximum) Amps Accuracy ±(0.2% + 2) Maximum Resolution 0.01 µA Current AC Maximum Amps 10 A (20 A for 30 seconds maximum) Amps Accuracy ±(1.0% + 2) True RMS Maximum Resolution 0.1 µA Resistance Maximum Resistance 50 MΩ Accuracy ±(0.2% + 1) Maximum Resolution 0.1Ω Capacitance Maximum Capacitance 9,999 µF Accuracy ±(1% + 2) Maximum Resolution 0.01 nF Frequency Maximum Frequency 200 kHz Accuracy ±(0.005% + 1) Maximum Resolution 0.01 Hz Duty Cycle Maximum Duty Cycle 99.9% Accuracy ±(0.2% per khz +0.1%) Maximum Resolution 0.1% Temperature Measurement -200.0°C - 1090°C
-328.0°F - 1994.0°F
excluding probe80 BK Temperature Probe -40.0°C - 260°C
-40.0°F - 500°F, 2.2°C or 2% whichever is greaterConductance Maximum Conductance 60.00 nS Accuracy ±(1.0% + 10) Maximum Resolution 0.01 nS Diode Range 3 V Resolution 1 mV Accuracy ±(2% + 1) Duty Cycle Range Accuracy Within ±(02% per kHz +0.1%) Environmental Specifications Operating Temperature -20°C to +55°C Storage Temperature -40°C to +60°C Humidity (Without Condensation) 0% - 90% (0°C - 35°C)
0% - 70% (35°C - 55°C)Operating Altitude 2000 m Safety Specifications Overvoltage category EN 61010-1 to 1000 V CAT III, 600V CAT IV Agency Approvals UL, CSA, TÜV, VDE listed Mechanical and General Specifications Size 201 x 98 x 52 mm (with holster) Weight 355 g
624 g - with holsterDisplay Digital 6000 counts updates 4/sec.
19,999 counts in high-resolution modeAnalog 32 segments, updates 40/sec. Frequency 19,999 counts, updates 3/sec at > 10 Hz Warranty Lifetime Battery Life Alkaline ~400 hours typical, without backlight Shock 1 Meter drop per IEC 61010-1:2001 Vibration Per MIL-PRF-28800 for a Class 2 instrument
Fluke 115 Digital Multimeter
With its simple operation, compact design and ease of use, the Fluke 115 True RMS digital ultimeter provides the perfect answer for general purpose electrical and electronic test requirements. The Fluke 115 displays True RMS voltage and current readings with 600 count resolution, continuity and capacitance, making it perfect for quick verifications and field service use.
Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V Environments.
Features:
Fluke 115 Digital Multimeters are independently tested for safe use in CAT III 600V Environments.
Features:
- Large white LED backlight to work in poorly lit areas
- Resistance and continuity
- Frequency and capacitance
- Maximum Voltage ac/dc 600V
- 10A ac/dc current measurement (20 A overload for 30-seconds max)
- Min/Max/Average to record signal fluctuations
- CAT III 600 V safety rated
- Safety conformance
| Specifications | |||
| Maximum voltage between any terminal and earth ground | 600 V | ||
| Surge protection | 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 | ||
| Display | Digital: 6,000 counts, updates 4 per second | ||
| Bar graph | 33 segments, updates 32 per second | ||
| Operating temperature | -10°C to + 50°C | ||
| Storage temperature | -40°C to + 60°C | ||
| Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | ||
| Battery life | 400 hours typical, without backlight | ||
| Accuracy Specifications | |||
| DC millivolts | Range/resolution | 600.0 mV / 0.1 mV | |
| Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | ||
| DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V | |
| Accuracy | ± ([% of reading] + [counts]): 0.5% + 2 | ||
| AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV | |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | ||
| AC volts1 True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V | |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | ||
| Continuity | Range/resolution | 600 Ω / 1 Ω | |
| Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. | ||
| Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ | |
| Accuracy | 0.9% + 1 | ||
| Range/resolution | 40.00 MΩ / 0.01 MΩ | ||
| Accuracy | 5% + 2 | ||
| Diode test | Range/resolution | 2.00 V / 0.001 V | |
| Accuracy | 0.9% + 2 | ||
| Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF | |
| Accuracy | 1.9% + 2 | ||
| Range/resolution | > 1000 μF | ||
| Accuracy | 5% + 20% | ||
| Lo-Z capacitance | Range | 1 nF to 500 μF | |
| Accuracy | 10% + 2 typical | ||
| AC amps True RMS (45 Hz to 500Hz) | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A | |
| Accuracy | 1.5% + 3 20 A overload for 30-seconds max | ||
| DC amps | Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A | |
| Accuracy | 1.0% + 3 20 A overload for 30-seconds max | ||
| Hz (V or A input)2 | Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.01 Hz 9.999 kHz / 0.001 kHz 50 kHz / 0.01 kHz | |
| Accuracy | 0.1% + 2 | ||
| 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Frequency is AC coupled, 5Hz to 30 kHz for AC voltage. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 2. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 2. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | |||
| Mechanical & General Specifications | |||
| Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | ||
| Weight | 550 g | ||
Siglent SHS806 Handheld Oscilloscope, 60MHz, 2-Channel
The Siglent SHS806 is a 60MHz handheld, two-channel digital oscilloscope for viewing electrical signals and has a 6,000-count multimeter mode for measuring AC and DC voltage. The oscilloscope has a real-time sample rate of 1GS/s and a record length of 2Mpts for acquiring detailed waveforms. Four math functions plus FFT (fast fourier transform), and automatic and cursor measurements allow an in-depth analysis of waveforms. Edge, Pulse, Video, Slope, and Alternative triggers allow isolation of specific signals. The oscilloscope's automatic triggering recognizes signal patterns and optimizes triggering, timebase and amplitude settings. The oscilloscope has a recorder that captures up to 18 hours of waveforms.
Additional specifications include a rise time of 5.8ns. The unit has a 5.7" color TFT-LCD. The oscilloscope has a USB host port for storing data on a 4GB-maximum flash drive and a USB device port for connecting to a compatible PC. Operating menus and help display in Simplified Chinese, Traditional Chinese, English, Arabic, French, German, Russian, Portuguese, Spanish, Japanese, Korean, and Italian languages. The unit operates on a rechargeable battery pack or a 100 to 240V AC, 50/60Hz adapter/charger (both included). It meets CAT II 300V and CAT III 300V safety standards.
Specifications
- Bandwidth 60MHz
- Channels Two
- Display 5.7" TFT-LCD (320 x 234 pixels)
- Power 100 to 240V power adapter, 7.4V 5000mAh battery pack
- Weight 1.5kg
- Dimensions (H x W x D) 260 x 163 x 53 mm
H is height, the vertical distance from the lowest to highest point; W is width, the horizontal distance from left to right; D is depth, the horizontal distance from front to back.
Oscilloscopes are electrical testing devices used to verify the functionality of an electrical signal generator. Oscilloscopes measure an electrical signal over time, and display the waveform signals in a visual graph. The waveform shows the sweeps (or refresh) of voltage on a vertical (Y) axis, and can display time on a horizontal (X) axis. Details of a waveshape demonstrate the signal over time. Oscilloscopes can display in a digital or analog view. An analog oscilloscope has continuous waveform display, typically in a luminous phosphor. Some oscilloscopes can display more than one channel and type of measurement simultaneously. Some oscilloscopes can capture waveform signals to memory, and recall them. Oscilloscopes may provide real-time intensity grading. Some oscilloscopes have the ability to adjust frequency of display. A constant image will display if a signal is shown at a high frequency. Oscilloscopes can be powered with batteries or electricity, or may have a built-in generator. They may have Canadian Standards Association (CSA) or European Conformity (CE) certification, or a specific category (CAT) safety rating, such as CAT5e. Oscilloscopes are commonly used for testing, measuring, and inspecting in science, engineering, telecommunications, automotive, and industry applications.
Siglent manufactures electronics test and measurement instruments for research and development, production-line testing, and electronic field service applications. The company, founded in 2002 and headquartered in Shenzhen, China, meets International Organization for Standardization (ISO) standards 9001:2000 and 14001:2004.
What's in the Box?
- SHS806 handheld oscilloscope
- (2) Oscilloscope probes
- (2) Multimeter probes
- Multimeter pen
- USB cable
- Power cord
- User manual
- Software
Product Features
- 60MHz handheld, two-channel digital oscilloscope for viewing electrical signals with multimeter mode for measuring voltage, frequency, duty cycle, and power
- Real-time sample rate of 1GS/s and record length of 2Mpts for acquiring up to 18 hours of detailed waveforms
- Advanced triggers for isolation of specific signals
- 5.7" color TFT-LCD with an internal 8 x 12 division grid for viewing waveforms
- Meets CAT II 300V and CAT III 150V safety rating
Specifications for this item
| Brand Name | Siglent |
|---|---|
| Part Number | SHS806 |
| UPC | 519805775704 |
| Body Style | handheld |
| Display | 5.7" color TFT-LCD |
Siglent SHS810 oscilloscope
Siglent SHS810 Handheld Oscilloscope ( 100MHz, 2 Channel)
The SHS810 is a portable oscilloscope that is ideally suited for use in outdoor applications, circuit measurements, wind power, PV and new energy equipment testing, automotive electron and electric automobile testing, electrical power systems and strong electricity testing, electrical debug testing, education, scientific research and quality control. In fact this device is more than just a digital handheld oscilloscope; the SHS810 is a combined unit which includes an oscilloscope, multimeter and recorder for documenting waveforms using Trendplot and waveform Recorder.
All of this is built into the same unit, making this product ideal for a wide range of different testing scenarios like those listed above. This product features bandwidth of 100MHz and is able to measure both single channel (with real time sampling rate of 1GSa/s) and double channel (real time sampling rate of 500MSa/s) and has overall memory depth of 2Mpts. The screen of this device is 5.7 inches in size, and is full-colour for easy waveform tracking and viewing. The in-built multimeter in the device is capable of measuring DC/AC Voltage, DC/AC current, resistance, diode, capacitance and continuity. Additional features of this product include rise time of ≤5.8ns, input impedance of 1MΩ±2%, 18pf±3pf, equivalent sampling rate of 50GS/s and multiple trigger types (Edge, Pulse, Video, Slope and Alternative).
| Type | SHS806 | SHS810 | SHS815 | SHS820 |
| Bandwidth | 60MHz | 100MHz | 150MHz | 200MHz |
| Rise Time | ≤5.8ns | ≤3.5ns | ≤2.3ns | ≤1.7ns |
| Input Impedance | 1MΩ±2%, 18pf±3pf | |||
| Real Time Sampling Rate | Single Channel: 1GSa/s, Double Channels: 500MSa/s | 500MSa/s | ||
| Equivalent Sampling Rate | 50GSa/s | |||
| Time Base Range | 5 ns/ div – 50s/ div | 2.5 ns/ div – 50s/ div | ||
| Scan Range | 100ms/ div ~ 50s/ div | |||
| Vertical Sensitivity | 2mV/div – 100V/div(1-2-5 step) | |||
| Vertical Resolution | 8 bits | |||
| Trigger Types | Edge, Pulse, Video, Slope, Alternative | |||
| Frequency Counter | 6 bits | |||
| Connection | USB Device, USB Host | |||
| Math | +, -, * , /, FFT | |||
| Oscilloscope Trend Plot | 800K points | |||
Products Included
- Siglent SHS806 Handheld Oscilloscope
- 9V, 4A Power Adapter
- Two 1X/10X Oscilloscope Probes
- Two Test Leads for Multimeter
- Probe Calibration Accessory
- USB Data Transmitting Cable
- User Manual
- Warranty Card
- Easyscope Software (Used for PC control)
Friday, April 01, 2016
Basic Interface Shield for Arduino
A shield modules / add-on for Arduino / Compatible.
The shield can also be used for learning communication via ethernet (W5500), SPI (MMA7455L), I2C (DS1307) and UART.
specifications:
- W5500 (ethernet).
- SPI (MMA7455L): 3-axis accelerometer sensor.
- RTC DS1307 (I2C)
- 2x Tactile switch as an input.
- 2x LED (blue and red) as an indicator light.
- Power Supply: Taken from the Arduino board.
- Dimensions: 6.11 cm (L) x 5.34 cm (L) x 2.4 cm (T)
HDPM01 Compass module with altitude
HDPM01 module includes a pressure module and a compass module
The HDPM01 pressure module includes a piezo-resistive pressure sensor and an ADC interface. It provides 16 bit word data for pressure and temperature related voltage. With the help of a highly accurate calibration of the senor, 11 unique coefficients were stored on the chip, thus accurate pressure and temperature reading can be realized. HM03 is a low power, low voltage device with automatic power down switching. I2C Serial Interface is used for communications with a microprocessor. Sensor packaging options are SMD (with metal cap)
The HDPMO1 is a dual-axis magnetic sensor, it is a complete sensing system with on-chip signal processing and integrated I2C bus, allowing the device to be connected directly to a microprocessor eliminating the need for A/D converters or timing resources. It can measure magnetic field with a full range of ±2 gausses and a sensitivity of 512counts/gauss @3.0 V at 25°C.
Features
- Supply voltage 2.2v-3.6v
- -20°C to + 60°C operating range
- No external components required
- I2C digital output with 400 KHz, fast mode operation.
Applications
- Pressure measurement and control systems
- Mobile altimeter/barometer systems
- Weather forecast products
- Adventure or multi-mode watches
- Electronic Compass
- GPS Navigation
- Position Sensing
- Vehicle Detection
- Magnetometry
Subscribe to: