Input Voltage | 88 ~ 264Vac 124 ~ 370Vdc |
Input Frequency | 47 ~ 63Hz |
Power Factor (Typ.) | PF>0.95/230Vac PF>0.95/115Vac at full load |
Input Current | 7A/115Vac 3.5A/230Vac |
Inrush Current | 18A/115Vac 36A/230Vac |
Leakage Current | <3.5mA/240Vac |
Set Up, Rise Time | 1500ms, 50ms at full load |
Hold Time (Typ.) | 24ms at full load |
Voltage Tolerance | ±1.0% |
Line Regulation | ±0.5% |
Load Regulation | ±0.5% |
Over Load Protection | 105 ~ 135% rated output power |
| Fold back current limiting, recovers automatically after fault condition is removed |
Over Voltage Protection | Hiccup mode, recovers automatically after fault condition is removed |
Fan Control O.T.P. | RTH1 or RTH2 >50°C FAN ON, <45°C FAN OFF, >70°C output shutdown |
Remote Control | RC+/RC-: Short = power on ; Open = power off |
Working Temperature | -10°C ~ +50°C (Refer to output load derating curve) |
Working Humidity | 20 ~ 90% RH non-condensing |
Storage Temperature, Humidity | -20°C ~ +85°C, 10 ~ 95% RH |
Temperature Coefficient | ±0.03%/°C (0°C ~ 50°C) |
Vibration | 10 ~ 500Hz, 2G 10min./1cycle, period for60min. each along X, Y, Z axes |
Withstand Voltage | I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
Isolation Resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
Safety Standards | UL60950-1, TUV EN60950-1 Approved |
EMC | Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,-3; |
| EN61000-4-2,3,4,5,6,8,11; ENV50204, Light industry level, criteria A |
MTBF | 133.4K hrs min. MIL-HDBK-217F (25°C) |