Tuesday, January 08, 2013

Hantek DSO-5062B 60MHz digital storage oscilloscope

Hantek DSO-5062B 60MHz digital storage oscilloscope
Bandwidth:60,1GSa/s Real Time sample rate Large (7.0-inch) color display,WVGA(800x480) Record length up to 1M


Features
• 60MHz bandwidths
•1GSa/s Real Time sample rate
• Large (7.0-inch) color display,WVGA(800x480)
• Record length up to 1M
• Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
• USB host and device connectivity, standard
• Multiple automatic measurements
• Four math functions, including FFTs standard
• Provides software for PC real-time analysis

Technical Specs:

Bandwidth


60MHz
Real-time Sample Rate
1GSa/s
Equivalent Sample Rate
25GSa/s
Record Length(Sample Points)
Single-channel: Maximum 1M; Dual-channel:Maximum 512K (4K,16K,40K optional)
SEC/DIV Range
4nS/div-40S/div (in a 2, 4, 8 sequence)
Delay Time Accuracy
500ps
Vertical
A/D Converter
8-bit resolution, each channel sampled simultaneously
VOLTS/DIV Range
2mV/div5V/div at input BNC
Position Range
±50V(5V/div),±40V(2V/div500mV/div),2V(200mV/div50mV/div)±400mV(20mV/div2mV/div)
Rise Time at BNC


≤5.8ns
DC Gain Accuracy
±4% for Sample or Average acquisition mode, 5mV/div to 2mV/div
±3% for Sample or Average acquisition mode, 5V/div to 10mV/div
Trigger
Trigger Sensitivity
(Edge Trigger Type)
DC: CH1/CH2(Typical) 1div from DC to 10MHz;1.5div from 10MHz to Full
EXT
Typical 200mV from DC to 40MHz
EXT/5
Typical 1V from DC to 40MHz
AC: Attenuates signals below 10Hz

HF Reject: Attenuates signals above 80kHz

LF Reject: Attenuates signals below 150kHz

Noise Reject: Reduces trigger sensitivity
Trigger Level Range
CH1,CH2: ±8 divisions from center of screen
EXT: ±1.2V EXT/5: ±6V
Trigger Level Accuracy,
typical (Accuracy is for signals having rise and fall times ≥20ns)
CH1,CH2: ±(0.3div×V/div) (within ±4 divisions from center of screen)
EXT: ±(6% of setting + 40mV)
EXT/5: ±(6% of setting + 200mV)
Holdoff Range
100ns-10s
Trigger Type
Edge
Trigger on the rising or falling edge
Pulse Width
Trigger (when >,<,=,≠) on positive or negative pulses
Pulse Width Range: 20ns-10s
Video
Trigger on an NTSC, PAL, or SECAM standard video signal
Line Range: 1-525 (NTSC), 1-625 (PAL/SECAM)
Slope
Trigger (when >,<,=,≠) on a positive or negative slope
Set Time: 20ns–10s
Overtime
from the rising or falling edge
Set Time: 20-10s
Alternate
Internal trigger on edge, pulse width, video or slope
Measurement
Cursors
Manual: The difference between voltage cursors V; the difference between time cursors T; 1/T calculated by Hz.
Tracing: The voltage and time at a waveform point
Automatic
Pk-Pk, Max, Min, Mean, Cyc RMS, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width
Display
Type
Right angle 7"TFT 16-digit color LCD
Resolution
800*480 dots
Contrast
16 gears, with the progress bar to show adjustment
Interface
USB host and USB slave
Power Supply
Voltage
100-120VACRMS(±10%)45Hz to 440HzCAT
120-240VACRMS(±10%)
45Hz to 66HzCAT
Power
<30w span="span">
Fuse
2A, T rating, 250V
Mechanical
Size
Length: 313mm Width: 108mm Height: 142mm
Weight
2.08KG (exclusive of packing and accessories)

 Software:

Operating system: Windows 7, Windows NT, Windows 2000, Windows XP ,VISTA

Note: This device is running Linux 2.6