RS485 is widely used in electronics system. PLC-RS485 modem from LinkSprite uses LinkSprite PLC-RS485 module,and isdesigned to send/receive RS485 data over the powerline network. PLC-RS485 is designed to transparently move serial data over the powerline network.
LinkSprite modules have the built-in packet-level repeater function. This feature can greatly extend the coverage of the powerline communication.
LinkSprite modules has both physical and logic addresses. In a network, both physical and logic addresses can be used to address different nodes in the network.
Features
- Fully transparent mode, plug and play coming out of the box without the need to do any programming.
- Built-in error correction codes.
- Built-in repeater function to extend the coverage.
- Physical and logic address
- AT commands used for advanced configuration.
- RS485 interface to host uP
- FSK(Frequency Shift Keying) modulation used in physical layer
- Low power Design
- RoHS
- Small module size, and easy to be implemented into existing products.
Specifications
| Product name | PLC-FSK-RS485-CASE |
| Interface | RS485 |
| Powerline Voltage | 230VAC/50Hz,110VAC/60Hz |
| Modulation | FSK(Frequency Shift Keying) |
| Carrier frequency | 262K/144KHz |
| Error Correction | FEC(Forward Error Correction) |
| Data rate on Powerline | 2Kbps |
| Maximum packet data length | 320bytes |
| Repeater Hops | 3 Hops |
| Transmission distance | 300 feets(no repeater) |
| Support nodes number | 65535 |
| LED | Power Line Activity LED system LED serial port LED |