3000A Dual Display Clamp-On Meter -HP-860B
Basic function
DC Voltage 60mV~1000V
AC Voltage 60mV~750V
DC Ccrrent 400A~3000A
AC Ccrrent 400A~3000A
Resistance 600Ω~60MΩ
Capacitance 40nF~4000uF
Temperature -20℃~1000℃
Frequency 10Hz~10MHz
Duty Cycle 0.1%~99.9%
AC Voltage 60mV~750V
DC Ccrrent 400A~3000A
AC Ccrrent 400A~3000A
Resistance 600Ω~60MΩ
Capacitance 40nF~4000uF
Temperature -20℃~1000℃
Frequency 10Hz~10MHz
Duty Cycle 0.1%~99.9%
Express function
Display 5999
Range Select Auto
Diode Test √
Continuity Buzzer √
Date Hold √
Back Light √
Auto Power Off √
℃/℉ √
Relative Value √
Bar Graph Display √
Dual Display √
Jaw Caliber 65mm
Range Select Auto
Diode Test √
Continuity Buzzer √
Date Hold √
Back Light √
Auto Power Off √
℃/℉ √
Relative Value √
Bar Graph Display √
Dual Display √
Jaw Caliber 65mm
General Features
Battery Type 9V(6F22)x1
Dimension 275x120x33mm
Weight 560g
MOQ 50
Dimension 275x120x33mm
Weight 560g
MOQ 50
Function | Range |
Accuracy
|
Resolution
|
Remarks
| |||
DCV
|
60mV
|
± 0.8% of rdg
|
0.01mV
|
Overload protection: 1000V DC or 750V AC rms
Impedance: 10MΩ
| |||
600mV
|
±0.5% of rdg
|
0.1mV
| |||||
6V
|
1mV
| ||||||
60V
|
10mV
| ||||||
600V
|
100mV
| ||||||
1000V
|
±0.8% of rdg
|
1V
| |||||
ACV
|
Range
|
Accuracy
|
Resolution
|
Frequency: 40~400Hz
Overload protection: 1000V DC or 750V AC rms
Impedance: 10MΩ
| |||
60mV
|
±2.0% of rdg
|
0.01mV
| |||||
600mV
|
0.1mV
| ||||||
6V
|
1mV
| ||||||
60V
|
±1.5% of rdg
|
10mV
| |||||
600V
|
100mV
| ||||||
750V
|
±2.0% of rdg
|
1V
| |||||
DCA
|
Range
|
Accuracy
|
Resolution
|
Overload protection: 3000A DC or AC rms
| |||
400A
|
±3.0% of rdg
|
0.1A
| |||||
3000A
|
0-1000
|
± 3.5% of rdg
|
1A
| ||||
1000-2000
|
± 5.5% of rdg
|
1A
| |||||
2000-3000
|
± 6.5% of rdg
|
1A
| |||||
ACA
|
Range
|
Accuracy
|
Resolution
|
Frequency: 40~60Hz
Overload protection: 3000A DC or AC rms
| |||
400A
|
± 3.5% of rdg
|
0.1A
| |||||
3000A
|
0-1000
|
± 3.5% of rdg
|
1A
| ||||
1000-2000
|
± 5.5% of rdg
|
1A
| |||||
2000-3000
|
± 6.5% of rdg
|
1A
| |||||
Resistance | Range |
Accuracy
|
Resolution
|
Overload protection: 250V DC or AC rms
| |||
600Ω
|
± 1.2% of rdg
|
0.1Ω
| |||||
6kΩ
|
1Ω
| ||||||
60kΩ
|
10Ω
| ||||||
600kΩ
|
100Ω
| ||||||
6MΩ
|
1kΩ
| ||||||
60MΩ
|
± 2.5% of rdg
|
10kΩ
| |||||
Capacitance
|
Range
|
Accuracy
|
Resolution
|
Overload protection: 250V DC or AC rms
| |||
40nF
|
± 5.0% of rdg
|
10pF
| |||||
400nF
|
± 2.5% of rdg
|
100pF
| |||||
4µF
|
1nF
| ||||||
40µF
|
± 5.0% of rdg
|
10nF
| |||||
400µF
|
± 20.0% of rdg
|
100nF
| |||||
4000µF
|
1µF
| ||||||
Diode and Audible continuity test
|
Range
|
Description
|
Test condition
|
Overload protection: 250V DC or AC rms
| |||
Display read
approximately
forward voltage
of diode
|
Forward DC current
approx. 0.4mA
Reversed DC voltage
approx. 2.8V
| ||||||
Built-in buzzer
sounds if
resistance is
less than 100Ω
|
Open circuit voltage
approx. 0.5V
| ||||||
Frequency
|
Range
|
Accuracy
|
Resolution
|
Sensitivity: Range of input voltage:1.5V~10V, If input voltage over range,need adjust
Overload protection: 250V DC or AC rms
| |||
10HZ
|
± 0.5% of rdg
|
0.01HZ
| |||||
100HZ
|
0.1HZ
| ||||||
1000HZ
|
1HZ
| ||||||
10KHZ
|
10HZ
| ||||||
100KHZ
|
100HZ
| ||||||
1000KHZ
|
1KHZ
| ||||||
10MHZ
|
10KHZ
| ||||||
Temperature
|
Accuracy
|
Resolution
|
NiCr-NiSi sensor
Overload protection: 36V DC or AC rms
| ||||
-20~150℃
-4~302℉
|
± 3℃+2
|
1℃/1℉
| |||||
150~300℃
302~572℉
|
± 3% of rdg
| ||||||
300~1000℃
572~1832℉
|
± 3.5% of rdg
| ||||||