Basic function
Range
DC Voltage 60mV~1000V
AC Voltage 60mV~750V
AC Ccrrent 400A~3000A
Resistance 600Ω~60MΩ
Capacitance 40nF~4000uF
Temperature -20℃~1000℃
Frequency 10Hz~10MHz
Duty Cycle 0.1%~99.9%
DC Voltage 60mV~1000V
AC Voltage 60mV~750V
AC Ccrrent 400A~3000A
Resistance 600Ω~60MΩ
Capacitance 40nF~4000uF
Temperature -20℃~1000℃
Frequency 10Hz~10MHz
Duty Cycle 0.1%~99.9%
Express function
Display 5999
Range Select Auto
Diode Test √
Continuity Buzzer √
Date Hold √
Back Light √
Auto Power Off √
℃/℉ √
Relative Value √
MAX/MIN √
Bar Graph Display √
Dual Display √
Jaw Caliber 65mm
Range Select Auto
Diode Test √
Continuity Buzzer √
Date Hold √
Back Light √
Auto Power Off √
℃/℉ √
Relative Value √
MAX/MIN √
Bar Graph Display √
Dual Display √
Jaw Caliber 65mm
General Features
Battery Type 9V(6F22)x1
Dimension 275x120x33mm
Weight 560g
MOQ 50
Dimension 275x120x33mm
Weight 560g
MOQ 50
Function | Range |
Accuracy
|
Resolution
|
Remarks
| ||||
DCV
|
60mV
|
±0.8% of rdg
|
0.01mV
|
Overload protection: 1000V DC or 750V AC rms
Impedance: 10MΩ
| ||||
600mV
|
±0.5% of rdg
|
0.1mV
| ||||||
6V
|
1mV
| |||||||
60V
|
10mV
| |||||||
600V
|
100mV
| |||||||
1000V
|
±0.8% of rdg
|
1V
| ||||||
ACV
|
Range
|
Accuracy
|
Resolution
|
Frequency: 40~400Hz
Overload protection: 1000V DC or 750V AC rms
Impedance: 10MΩ
| ||||
60mV
|
±2.0% of rdg
|
0.01mV
| ||||||
600mV
|
0.1mV
| |||||||
6V
|
1mV
| |||||||
60V
|
±1.5% of rdg
|
10mV
| ||||||
600V
|
100mV
| |||||||
750V
|
±2.0% of rdg
|
1V
| ||||||
ACA
|
Range
|
Accuracy
|
Resolution
|
Frequency: 40~60Hz
Overload protection: 3000A DC or AC rms
| ||||
400A
|
±3.5% of rdg
|
0.1A
| ||||||
3000A
|
0-1000
|
±3.5% of rdg
|
1A
| |||||
1000-2000
|
±5.5% of rdg
|
1A
| ||||||
2000-3000
|
±6.5% of rdg
|
1A
| ||||||
Resistance | Range |
Accuracy
|
Resolution
|
Overload protection: 250V DC or AC rms
| ||||
600Ω
|
±1.2% of rdg
|
0.1Ω
| ||||||
6kΩ
|
1Ω
| |||||||
60kΩ
|
10Ω
| |||||||
600kΩ
|
100Ω
| |||||||
6MΩ
|
1kΩ
| |||||||
60MΩ
|
±2.5% of rdg
|
10kΩ
| ||||||
Capacitance
|
Range
|
Accuracy
|
Resolution
|
Overload protection: 250V DC or AC rms
| ||||
40nF
|
±5.0% of rdg
|
10pF
| ||||||
400nF
|
±2.5% of rdg
|
100pF
| ||||||
4µF
|
1nF
| |||||||
40µF
|
±5.0% of rdg
|
10nF
| ||||||
400µF
|
±20.0% of rdg
|
100nF
| ||||||
4000µF
|
1µF
| |||||||
Diode T and Audible continuity test
|
Range
|
Description
|
Test condition
|
Overload protection: 250V DC or AC rms
| ||||
Display read
approximately
forward voltage
of diode
|
Forward DC current
approx. 0.4mA
Reversed DC voltage
approx. 2.8V
| |||||||
Built-in buzzer
sounds if
resistance is
less than 100Ω
|
Open circuit voltage
approx. 0.5V
| |||||||
Frequency
|
Range
|
Accuracy
|
Resolution
|
Sensitivity
|
Sensitivity: Range of input voltage:1.5V~10V, If input voltage over range,need adjust
Overload protection: 250V DC or AC rms
| |||
10Hz
|
±0.5% of rdg
|
0.01Hz
| ||||||
100Hz
|
0.1Hz
| |||||||
1000Hz
|
1Hz
| |||||||
10kHz
|
10Hz
| |||||||
100kHz
|
100Hz
| |||||||
1000kHz
|
1kHz
| |||||||
10MHz
|
10kHz
| |||||||
Temperature
|
Range
|
Accuracy
|
Resolution
|
Overload protection: 36V DC or AC rms
| ||||
℃/℉
|
-20~150℃
-4~302℉
|
± (3℃+2)
|
1℃/1℉
| |||||
150~300℃
302~572℉
|
± 3% of rdg
| |||||||
300~1000℃
572~1832℉
|
± 3.5% of rdg
| |||||||