Auto Range Digital Clamp Meter -HP-870CR
Basic function
DC Voltage 400mV~1000V
AC Voltage 400mV~750V
DC Current 200A~1000A
AC Current 400A~1000A
Resistance 400Ω~40MΩ
Capacitance 40nF~100uμF
Temperature -20℃~1000℃
Frequency 10Hz~10MHz
Duty Cycle 0.1%~99.9%
AC Voltage 400mV~750V
DC Current 200A~1000A
AC Current 400A~1000A
Resistance 400Ω~40MΩ
Capacitance 40nF~100uμF
Temperature -20℃~1000℃
Frequency 10Hz~10MHz
Duty Cycle 0.1%~99.9%
Express function
Display 3999
Range Select Auto
Diode Test √
Continuity Buzzer √
Data Hold √
Back Light √
Auto Power Off √
Relative Value √
AC Ture RMS √
Dual Display √
Jaw Caliber 45mm
Range Select Auto
Diode Test √
Continuity Buzzer √
Data Hold √
Back Light √
Auto Power Off √
Relative Value √
AC Ture RMS √
Dual Display √
Jaw Caliber 45mm
General Features
Battery Type 9V(6F22)x1
Dimension 230x85x40mm
Weight 450g
Dimension 230x85x40mm
Weight 450g
Function
|
Range
|
Accuracy
|
Resolution
|
Remarks
| ||||||
DCV
|
400mV
|
0.8% of rdg
|
0.1mV
|
Overload protection: 1000V DC/750Vrms AC
Impedance: 10MΩ,More than 100MΩ on 400mV scale
| ||||||
4V
|
1.0% of rdg
|
1mV
| ||||||||
40V
|
10mV
| |||||||||
400V
|
100mV
| |||||||||
1000V
|
1.5% of rdg
|
1V
| ||||||||
ACV
|
Range
|
Accuracy
|
Resolution
|
Frequency
|
Average sensing, calibrated to rms of sine wave
Overload protection: 1000V DC/750Vrms AC;Impedance: 10MΩ.
| |||||
4V
|
1.5% of rdg
|
1mV
|
50~400Hz
| |||||||
40V
|
10mV
| |||||||||
400V
|
100mV
| |||||||||
750V
|
2.5% of rdg
|
1V
|
50~100Hz
| |||||||
DCA
|
Range
|
Accuracy
|
Resolution
|
Frequency
|
Overload protection: 1000Arms within 60 seconds
| |||||
200A
|
3.0% of rdg
|
0.1A
|
-
| |||||||
1000A
|
0~800
|
3.5% of rdg
|
1A
| |||||||
800~1000
|
6.5% of rdg
| |||||||||
ACA
|
Range
|
Accuracy
|
Resolution
|
Frequency
|
Average sensing, calibrated to rms of sine wave
Overload protection: 1000Arms within 60 seconds
| |||||
400A
|
3.0% of rdg
|
0.1A
|
50~400Hz
| |||||||
1000A
|
0~800
|
3.5% of rdg
|
1A
| |||||||
800~1000
|
6.5% of rdg
| |||||||||
ACV
(True RMS)
|
Range
|
Resolution
|
Accuracy
|
Sensitivity
|
1. Input impedance : > 10MΩ Ohm ACV True RMS.
2. Overload protect : 1000V DCV or ACV peak value.
3. Press “Range” button for select ACV 400mV range.
| |||||
400mV
|
0.1mV
|
±2.0% of rdg
|
40Hz-1kHz
| |||||||
4V
|
1mV
|
±1.2% of rdg
|
40Hz-1kHz
| |||||||
40V
|
10mV
|
±1.2% of rdg
|
40Hz-10kHz
| |||||||
400V
|
100mV
|
±1.0% of rdg
|
40Hz-400Hz
| |||||||
750V
|
1V
|
±1.0% of rdg
|
40Hz-400Hz
| |||||||
Resistance
|
Range
|
Accuracy
|
Resolution
|
Overload protection: 250V DC/250Vrms AC
| ||||||
400Ω
|
1.5% of rdg+15 digits
|
0.1Ω
| ||||||||
4kΩ
|
1.2% of rdg
|
1Ω
| ||||||||
40kΩ
|
10Ω
| |||||||||
400kΩ
|
100Ω
| |||||||||
4MΩ
|
1kΩ
| |||||||||
40MΩ
|
2.5% of rdg
|
10kΩ
| ||||||||
Capacitance
|
Range
|
Accuracy
|
Resolution
|
Overload protection: 250V DC/250Vrms AC
| ||||||
40nF
|
6.0% of rdg
|
10PF
| ||||||||
400nF
|
3.5% of rdg
|
100PF
| ||||||||
4μF
|
1nF
| |||||||||
40μF
|
10nF
| |||||||||
100μF
|
6.0% of rdg
|
100nF
| ||||||||
Frequency
|
Range
|
Accuracy
|
Resolution
|
Sensitivity
|
Overload protection: 250V DC/250Vrms AC
| |||||
10Hz
|
1.2% of rdg
|
0.01Hz
|
Range of input voltage:1.5V~10V, If input voltage over range, need adjust
| |||||||
100Hz
|
0.1Hz
| |||||||||
1000Hz
|
0.8% of rdg
|
1Hz
| ||||||||
10kHz
|
10Hz
| |||||||||
100kHz
|
100Hz
| |||||||||
1000kHz
|
1kHz
| |||||||||
10MHz
|
2.0% of rdg
|
10kHz
| ||||||||
Temperature(NiCr-NiSi sensor)
|
Range
|
Accuracy
|
Resolution
|
Overload protection: 36V DC/36Vrms AC
| ||||||
℃
|
-20~150℃
|
3℃+2
|
1℃
| |||||||
150~300℃
|
3.0% of rdg
|
1℃
| ||||||||
300~1000℃
|
3.5% of rdg
|
1℃
| ||||||||
Diode and Audible continuity test
|
Range
|
Description
|
Test Condition
|
Overload protection: 250V DC/250Vrms AC
| ||||||
Display read approx.
Forward voltage of diode
|
Forward DC current
approx. 0.4mA
Reversed DC voltage
approx. 1.5V
| |||||||||
Built-in buzzer sounds
if resistance is less
than 90Ω
|
Open circuit voltage
approx. 0.5V
| |||||||||