Thursday, December 13, 2012

MQ136 Semiconductor Sensor for H2S (Hidrogen Sulfida)



Sensitive material of MQ136 gas sensor is SnO2, which with lower conductivity in clean air. When the target H2S gas exist, the sensor’s conductivity is more higher along with the gas concentration rising. Please use simple electrocircuit, Convert change of conductivity to correspond output signal of gas concentration.

MQ136 gas sensor has high sensitity to H2S. It has low sensitivity to normal combustible gases, which is with low cost and suitable for different application.

Character                                                                                                                                    
*Good sensitivity to H2S                                                 
* Long life and low cost                                           
* Simple drive circuit

Application                        
* Domestic H2S concentration detector
* Industrial H2S leakage detector
* Portable H2S detector

Technical Data                                      
Model No.
MQ136
Sensor Type
Semiconductor
Standard Encapsulation
Bakelite (Black Bakelite)
Detection Gas
H2S
Concentration
1-200ppm ( H2S )
Circuit
Loop Voltage
Vc
≤24V  DC
Heater Voltage
VH
5.0V±0.2V ACorDC
Load Resistance
RL
Adjustable
Character
Heater Resistance
RH
31Ω±3Ω(Room Tem.)
Heater consumption
PH
≤900mW
Sensing Resistance
Rs
2KΩ-20KΩ(in 50ppm SO2)
Sensitivity
S
Rs(in air)/Rs(50ppm SO2)≥3
Slope
α
≤0.6(R100ppm/R50ppm SO2)
Condition
Tem.  Humidity
20℃±2℃;65%±5%RH
Standard test circuit
Vc: 5.0V±0.1V;
  VH: 5.0V±0.1V
Preheat time
Over 48 hours