Wednesday, April 18, 2012

Hantek DSO-5202B 200MHz 1Gs/S LCD 7" Digital Oscilloscope

Hantek DSO-5202B 200MHz 1Gs/S LCD 7" Digital Oscilloscope


High quality Hantek DSO-5202B 200MHz 1Gs/S LCD 7" Digital Oscilloscope.

Features: 
  • 200MHz bandwidths. 
  • 1GSa/s Real Time sample rate. 
  • Large (7.0-inch) color display,WVGA(800x480). 
  • Dimensions (mm):313*108*142MM 
  • Record length up to 1M. 
  • Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
  • USB host and device connectivity, standard.
  • Multiple automatic measurements.
  • Four math functions, including FFTs standard.
  • Provides software for PC real-time analysis.
  • Operating system: Windows NT, Windows 2000, Windows XP ,VISTA.
  • Supply DEMO code (VC、VB、LABVIEW).





Technical details:
Model
DSO5202B
DSO5102B
DSO5062B
Bandwidth
200MHz
100MHz
60MHz
Real-time Sample Rate
1GSa/s
Equivalent Sample Rate
25GSa/s
Record Length(Sample Points)
Single-channel: Maximum 1M; Dual-channel:Maximum 512K (4K,16K,40K optional)
SEC/DIV Range
4nS/div-40S/div (in a 2, 4, 8 sequence)
Delay Time Accuracy
500ps
Vertical
A/D Converter
8-bit resolution, each channel sampled simultaneously
VOLTS/DIV Range
2mV/div~5V/div at input BNC
Position Range
±50V(5V/div),±40V(2V/div~500mV/div),2V(200mV/div~50mV/div)±400mV(20mV/div~2mV/div)
Rise Time at BNC
≤1.7ns
≤3.5ns
≤5.8ns
DC Gain Accuracy
±4% for Sample or Average acquisition mode, 5mV/div to 2mV/div
±3% for Sample or Average acquisition mode, 5V/div to 10mV/div
Trigger
Trigger Sensitivity
(Edge Trigger Type)
DC: CH1/CH2(Typical) 1div from DC to 10MHz;1.5div from 10MHz to Full
EXT(Typical) 200mV from DC to 40MHz
EXT/5(Typical) 1V from DC to 40MHz
AC: Attenuates signals below 10Hz
HF Reject: Attenuates signals above 80kHz
LF Reject: Attenuates signals below 150kHz
Noise Reject: Reduces trigger sensitivity
Trigger Level Range
CH1,CH2: ±8 divisions from center of screen
EXT: ±1.2V EXT/5: ±6V
Trigger Level Accuracy,
typical (Accuracy is for signals having rise and fall times ≥20ns)
CH1,CH2: ±(0.3div×V/div) (within ±4 divisions from center of screen)
EXT: ±(6% of setting + 40mV)
EXT/5: ±(6% of setting + 200mV)
Holdoff Range
100ns-10s
Trigger Type
Edge
Trigger on the rising or falling edge
Pulse Width
Trigger (when >,<,=,≠) on positive or negative pulses
Pulse Width Range: 20ns-10s
Video
Trigger on an NTSC, PAL, or SECAM standard video signal
Line Range: 1-525 (NTSC), 1-625 (PAL/SECAM)
Slope
Trigger (when >,<,=,≠) on a positive or negative slope
Set Time: 20ns–10s
Overtime
from the rising or falling edge
Set Time: 20-10s
Alternate
Internal trigger on edge, pulse width, video or slope
Measurement
Cursors
Manual: The difference between voltage cursors V; the difference between time cursors T; 1/T calculated by Hz.
Tracing: The voltage and time at a waveform point
Automatic
Pk-Pk, Max, Min, Mean, Cyc RMS, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width
Display
Type
Right angle 7"TFT 16-digit color LCD
Resolution
800*480 dots
Contrast
16 gears, with the progress bar to show adjustment
Interface
USB host and USB slave
Power Supply
Voltage
100-120VACRMS(±10%),45Hz to 440Hz,CAT
120-240VACRMS(±10%),45Hz to 66Hz,CAT
Power
<30W
Fuse
2A, T rating, 250V
Mechanical
Size
Length: 313mm Width: 108mm Height: 142mm
Weight
2.08KG (exclusive of packing and accessories)