Meanwell PS-15-12 switch mode power supply
specifications:
- Power supply input: 85-264 VAC or 120-370 VDC
- Voltage output: 12 VDC
- Output current: 1.25 A
- Efficiency: 77%
- Power: 15 W
- Features: Short circuit / overload / over temperature / over voltage protection, low ripple & noise
Friday, April 26, 2013
USB TO RS232 H-E
USB TO RS232 H-E Serial converter module from USB to RS-232
specifications:
- Power supply: powered bus (take the power supply from the USB line)
- The interface or port: USB
- Stories: RS-232 (DB-9 male port)
- Data rate: 115200 bps (max)
- Cable length: about 1.8 meters
- Feature: Equipped converter from port DB-9 to DB-25 (not for the parallel port), compatible for Windows XP/Vista/7, Linux, MAC OS
USB TO RS232 HE800A
USB TO RS232 HE800A
Features:
Features:
- Full compliance with USB Specification V1.1
- Meets All EIA-232 and ITU V.28 Specifications
- Support the RS232 Serial interface
- Support over 1Mbps data transfer rate
- Support automatic handshake mode
- Support remote wake-up and power management
- Windows 98/Me/2000/XP and Mac OS8/9 Support,win7
- USB full speed communication and bus powered
- Low Supply Current Than Competition(typical 3mA)
Dot Matrix Printer POS76, serial
Dot Matrix Printer POS76
| Paper Loading | Cramp/Full Eject |
| Paper Cutter | Optional Full / Partial cut |
| Cutter Reliability | 300,000 cuts |
| Printing Method | 9 pin Serial Impact Dot Matrix |
| Printing Resolution | 42cpl-210(whole dot)/420(half dot) |
| Effective Printing Width | 66 mm |
| Printing Speed | 4.4 lps (for 76mm paper) / 5.6lps (57mm paper) |
| Character Set | ANK,GB2312-80 (Chinese) |
| Print Font | ANK: 7 x7 / 5 x 7 Chinese: 15 x 16 |
| Characters per Line (cpl) | 42 / 35 |
| Bar code Support | |
| Paper End Sensor | Optional Paper Near End Sensor/ Paper End Sensor |
| Printer Interface | RS-232 |
| Emulation | ESC/POS |
| Driver | Windows98/2000/NT/XP |
| Power Supply (Adapter) | AC100 ~240V(± 10%), DC 24V, 2A |
| Mean Cycles Between Failure (MCBF) | 9 million lines |
| Paper Type | Plain Paper |
| Paper Width | 76.0± 0.5mm |
| Papaer Thickness | 50um -80um |
| Paper Roll Diameter | 80mm (max) |
| Roll Core Inner Diameter | 13mm |
| Operation Environment | 0~40℃ 10~80%RH |
| Storage Environment | –20~60℃10~90%RH |
| Dimension (WⅹHⅹD mm) | 160 x 248 x 142 mm |
| Net Weight | With cutter:1.9kg, without cutter:1.66kg |
Thursday, April 25, 2013
Vernier BTA to DIN Adapter
This adaptor allows you to use newer analog BTA sensors with older interfaces such as the ULI. New sensors used through this adaptor will not be able to Auto-ID. (female BTA to male 5-pin DIN)
Vernier Analog Proto Board Connector
This connector makes it easy to wire the signal from a Vernier analog sensor into a non-Vernier interface.
The connector fits into a standard prototyping board or National Instruments’ ELVIS prototyping board, providing easy access to the sensor lines. Vernier analog sensors require a 5 volt source and in most cases provide a 0 – 5 volt raw signal.
Vernier Salinity Sensor
The Salinity Sensor precisely measures the total dissolved salt content of ocean or brackish water.
The Salinity Sensor easily and precisely measures the total dissolved salt content in an aqueous solution. Measure water with a wide variety of salinities, from brackish water to ocean water, and even hyper-saline environments. You can also study how salinity affects buoyancy or monitor salinity values in estuaries where fresh water mixes with ocean water
Specifications
- Range of Salinity Sensor: 0 to 50 ppt (0 to 50,000 ppm)
- Resolution: 0.02 ppt (20 ppm)
- (LabQuest 2, LabQuest, LabQuest Mini, Go!Link, LabPro)
- Accuracy: ±1% of full-scale reading
- Response time: 98% of full-scale reading in 5 s.
- Temperature compensation: automatic from 5 to 35°C
- Temperature range (can be placed in): 0 to 80°C
- Cell constant: 10 cm-1
- Description: dip type, epoxy body, parallel platinum electrodes
- Dimensions: 12 mm OD and 150 mmlength
What’s Included
- Vernier Salinity Sensor
- User manual
Sensor Requirements
The Salinity Sensor requires a compatible interface and software to collect data. Interface and software sold separately.
Compatible Interfaces
The Salinity Sensor is compatible with these interfaces:
LabQuest 2LabQuest
LabQuest Mini
Go!Link
SensorDAQ
NXT Sensor Adapter
LabPro
Vernier EasyLink
CBL 2
TI-Nspire Lab Cradle
Vernier Dissolved Oxygen Probe
Use the Dissolved Oxygen Probe to determine the concentration of oxygen in aqueous solutions in the field or in the laboratory.
The Dissolved Oxygen Probe is great for biology, chemistry, ecology, or integrated science courses. It can be used to perform a wide variety of experiments to determine changes in dissolved oxygen levels, one of the primary indicators of the quality of an aquatic environment.
Built-in temperature compensation lets you calibrate in the lab, then make measurements outdoors without having to recalibrate.
Disposable caps with pre-fit membranes allow you to quickly and conveniently change membranes.
Calibrate in the units you choose: % dissolved oxygen, mg/L, or ppm dissolved oxygen
Specifications
- Range: 0 to 15 mg/L (or ppm)
- Accuracy: ±0.2 mg/L
- Response Time: 95% of final reading in 30 seconds, 98% in 45 seconds
- Resolution: 0.014 mg/L (LabQuest 2, LabQuest, LabQuest Mini, Go!Link, LabPro)
- Temperature Compensation: automatic from 5–35°C
- Pressure Compensation: manual
- Salinity Compensation: manual
- Minimum sample flow: 20 cm/second
What’s Included
- Vernier Dissolved Oxygen Probe (dissolved oxygen electrode with membrane cap)
- One replacement membrane cap
- Sodium Sulfite Calibration Standard (2.0 M Na2SO3) and MSDS sheet
- D.O. Electrode Filling Solution, MSDS sheet, and filling pipet
- Calibration bottle (empty, lid with hole)
- D.O. Polishing Strips (1 pkg)
- User Manual
Sensor Requirements
The Dissolved Oxygen Probe requires a compatible interface and software to collect data. Interface and software sold separately
Compatible Interfaces
The Dissolved Oxygen Probe is compatible with these interfaces:
- LabQuest 2
- LabQuest
- LabQuest Mini
- Go!Link
- SensorDAQ
- NXT Sensor Adapter
- LabPro
- Vernier EasyLink
- CBL 2
- TI-Nspire Lab Cradle
Wednesday, April 24, 2013
USB to TTL Converter (CP210)
CP210 USB to TTL converter combine the USB-232-1 (USB to Single RS232 Adapter) and TTL-232-1 (Port-powered RS232/TTL converter) allows you to convert USB to TTL/CMOS compatible levels and vice versa.
It can be used to set up APC220 RF wireless module.
It can be used as STC microcontroller program downloader.
The PCB color may vary and not the same as shown in the picture.
Specification
- Voltage: 5V
- Chip: Silicon Laboratories CP210x chip
Sabertooth Dual 60A 6V-30V Regenerative Motor Driver
The Sabertooth Dual 60A 6V-30V Regenerative Motor Driver is one of the most versatile, efficient and easy to use dual motor drivers. It is suitable for high powered robots - up to 120lbs in combat or up to 1000lbs for general purpose robotics. Out of the box, the Sabertooth can supply two DC brushed motors with up to 60A each. Peak currents of 120A per channel are achievable for a few seconds. Overcurrent and thermal protection means you'll never have to worry about killing the driver with accidental stalls or by hooking up too big a motor.
Features:
• Nominal Voltage: 6 - 30V
• Most versatile, efficient and easy to use dual motor drivers
• 60A continuous, 120A peak per channel
• Can supply two DC brushed motors with up to 60A each
It allows you to control two motors with: analog voltage, radio control, serial and packetized serial. You can build many different robots of increasing complexity for years to come with a Sabertooth.
Technical Specs:
• 6 - 30V nominal, 33.6V absolute maximum
• Synchronous regenerative drive
• Ultra-sonic switching frequency
• Thermal and overcurrent protection
• Lithium protection mode
• Input modes: Analog, R/C, simplified serial, packetized serial
Applications
• Combat robots up to 120lb
• Normal and hobby robots up to 1000lb
• Differential drive robots
• Electric vehicles, ride-on toys, scooters
Subscribe to:
Posts (Atom)