Friday, June 01, 2012

Goot KX-60R general purpose soldering iron

Goot KX-60R general purpose soldering iron
•Economically priced general purpose soldering iron.
•Compact and lightweight design for easy handling.
•Available with Longlife tip or Nickel plated conventional copper tip.


Goot KX-40R general purpose soldering iron

Goot KX-40R general purpose soldering iron 
•Economically priced general purpose soldering iron.
•Compact and lightweight design for easy handling.
•Available with Longlife tip or Nickel plated conventional copper tip.


Goot KX-30R general purpose soldering iron

Goot KX-30R general purpose soldering iron
Economically priced general purpose soldering iron. 

•Compact and lightweight design for easy handling. 
•Available with Longlife tip or Nickel plated conventional copper tip.

25-80 watt Dekko Soldering Gun 938N

25-80 watt Dekko Soldering Gun 938N
Feature:
adjustable power/heat 25/80 Watt - Push Switch, with Input Supply 220VAC/50/60Hz

60 watt Dekko Soldering Iron DS-60

60 watt Dekko Soldering Iron DS-60
Feature:
60 Watt power Consumption, with Input Supply 220VAC/50/60Hz

40 watt Dekko Soldering Iron DS-40

40 watt Dekko Soldering Iron DS-40
Feature:
40 Watt power Consumption, with Input Supply 220VAC/50/60Hz

30 watt Dekko Soldering Iron DS-30

30 watt Dekko Soldering Iron DS-30
Feature:
30 Watt power Consumption, with Input Supply 220VAC/50/60Hz

Advanced Compound Eye

Model:JMP-BE-1721 

Infrared compound eye, made up of several infrared infrared sensitization units, is an electronic part used to detect infrared ray. With only one port, it can read the strongness of infrared rays easily and automatically work out the directions of the maximum value and minimun value.
The following is the real compound eye.

Feature:

1. Standard Joinmax RCU four-line connector. Compatible with two-line I2C interface. It is convinient for user's DIY extention use.
2. With seven lamps, direction indicator points out direction of light source (that is, direction of the maximum value) easily.
3. No initialization is needed; digitalized controlling.
4. Data of surrounding environment can be read by using 12 commands.

Usage
Compound eye is mainly used to detect the surrounding infrared rays, whose strongness is called ray value. Compound eye is used widely, for example, to detect lighted candle in the firefighting competition, or to tell the ball direction in the soccer match.

Goot GS-104 sucker

Goot GS-104 sucker

-Lightweight, economical and powerful. Removes solder with a strong vacuum.
-Operation is comfortable and comes with self cleaning shaft for easy maintenance.
-Can be stored away quickly, easily and compactly by pushing the shaft inside the chamber while pressing the Vacuum Release button.

DS2422 1-Wire® Temperature/Data Logger with 8KB Datalog Memory

The DS2422 temperature/data logger combines the core functions of a fully featured data logger in a single chip. It includes a temperature sensor, real-time clock (RTC), memory, 1-Wire interface, and serial interface for an analog-to-digital converter (ADC), as well as control circuitry for a charge pump. The ADC and the charge pump are peripherals that can be added to build application-specific data loggers. Without an external ADC, the DS2422 functions as a temperature logger only. It measures the temperature and/or reads the ADC at a user-defined rate. Additionally, the DS2422 can store 8192 8-bit readings or 4096 16-bit readings taken at equidistant intervals ranging from 1 second up to 273 hours.

Key Features
  • Automatically Wakes Up, Measures Temperature and/or Reads an External ADC and Stores Values in 8KB of Datalog Memory in 8 or 16-Bit Format
  • On-Chip Direct-to-Digital Temperature Converter with 8-Bit (0.5°C) or 11-Bit (0.0625°C) Resolution
  • Sampling Rate from 1s up to 273hrs
  • Programmable Recording Start Delay After Elapsed Time or Upon a Temperature Alarm Trip Point
  • Programmable High and Low Trip Points for Temperature and Data Alarms
  • Quick Access to Alarmed Devices Through 1-Wire Conditional Search Function
  • 512 Bytes of General-Purpose Memory Plus 64 Bytes of Calibration Memory
  • Two-Level Password Protection of all Memory and Configuration Registers
  • Unique Factory-Lasered 64-Bit Registration Number Assures Error-Free Device Selection and Absolute Part Identity
  • Built-in Multidrop Controller Ensures Compatibility with Other Dallas Semiconductor 1-Wire Net Products
  • Directly Connects to a Single Port Pin of a Microprocessor and Communicates at up to 15.4kbps at Standard Speed or up to 125kbps in Overdrive Mode
  • -40°C to +85°C Operating Range
  • 2.8V to 3.6V Single-Supply Battery Operation
  • Low Power (1.2µA Standby, 350µA Active)


Applications/Uses
  • Data logging (with an external ADC and charge pump), the DS2422S could be used in many data logging functions, such as pressure monitoring, light sensor monitoring, logging thermocouple temperatures, etc.
  • Monitoring of refrigeration systems, and environmental or thermal management systems (HVAC).
  • Temperature-Critical Product Shipping and Storage, such as Fresh Produce, Pharmaceuticals, and Blood Products.