Friday, November 23, 2012

Arduino Due

The first Arduino board based on a 32-bit ARM core microcontroller.  Arduino Due is a microcontroller board based on the Atmel SAM3X8E ARM Cortex-M3 CPU,  It has 54 digital input/output pins.
(of which 12 can be used as PWM outputs), 12 analog inputs, 4 UARTs (hardware serial ports), a 84 MHz clock, an USB OTG capable connection, 2 DAC (digital to analog), 2 TWI, a power jack, an SPI header, a JTAG header, a reset button and an erase button.

The board contains everything needed to support the microcontroller; simply connect it to a computer with a micro-USB cable or power it with a AC-to-DC adapter or battery to get started. The Due is compatible with all Arduino shields that work at 3.3V and are compliant with the 1.0 Arduino pinout.

Features:

• Contains everything needed to support the microcontroller

• Power it with a AC-to-DC adapter or battery to get started
• Compatible with all Arduino shields that work at 3.3V
• Arduino board based on a 32-bit ARM core microcontroller


Technical Specs:
• Microcontroller: AT91SAM3X8E
• Operating Voltage: 3.3V
• Input Voltage (recommended): 7-12V
• Input Voltage (limits): 6-20V
• Digital I/O Pins: 54 (of which 12 provide PWM output)
• Analog Input Pins: 12
• Analog Outputs Pins: 2 (DAC)
• Total DC Output Current on all I/O lines: 130 mA
• DC Current for 3.3V Pin: 800 mA
• DC Current for 5V Pin: 800 mA
• Flash Memory: 512 KB all available for the user applications
• SRAM: 96 KB (two banks: 64KB and 32KB)
• Clock Speed: 84 MHz

Warning: Unlike other Arduino boards, the Arduino Due board runs at 3.3V. The maximum voltage that the I/O pins can tolerate is 3.3V. Providing higher voltages, like 5V to an I/O pin could damage the board.


Wednesday, November 21, 2012

Mirroring in Taiwan


http://2r-he.blogspot.com mirroring to http://2r-he.blogspot.tw in Taiwan.

Saturday, November 17, 2012

Dekko PS-605SW variable switching power supply 0-60 VDC 0-5 Ampere

Dekko PS-605SW variable switching power supply 0-60 VDC  0-5 Ampere


Specifications:
  • Switch mode power supply with Output rated value: 0-60VDC 0-5Ampere
  • Input Power Voltage : 220VAC +/- 10% at 50/60Hz
  • Recover time: <200ms 0.5amp="0.5amp" 50="50" by="by" current="current" li="li" load="load" min="min" varries="varries">
  • Ripple noise: <0 -="-" .8vrms=".8vrms" 1="1" 3a="3a" 5a="5a" 5hz="5hz" current="current" li="li" max="max" mhz="mhz" rms="rms">
  • Temperature Coefficient: <300ppm degc="degc" li="li">
  • Power/Load Stability: <0 .2=".2" 3ma="3ma" li="li">
  • Ripple Noise: <5ma li="li" rms="rms">

Dekko PS-305-2 Laboratory regulated DC power supply

Dekko PS-305-2  Dual separated output , regulated power supply Laboratory standard.


Specifications:
  • Dual Separated Output rated value: 0-30VDC 0-5Ampere
  • Reference voltage DC 5V/1Amp
  • Input Power Voltage : 110/220VAC +/- 10% at 50/60Hz
  • Recover time: <100ms li="li" loa="loa">
  • z - 1 MHz Max Current < 3A ; <1 -="-" .0vrms=".0vrms" 1="1" 5a="5a" 5hz="5hz" current="current" li="li" max="max" mhz="mhz">
  • Temperature Coefficient: <300ppm degc="degc" li="li">
  • Power/Load Stability: <0 .2=".2" 3ma="3ma" li="li">
  • Ripple Noise: <3ma li="li" rms="rms">

Friday, November 16, 2012

ISO-A4-P3-O5 isolated current to voltage converter


Isolated amplifier to convert the analog signal in the form of current into a voltage. IC is commonly used in analog data acquisition applications, interface with analog sensors, long-distance signal transmission, etc..

specifications:
- Signal input 4mA - 20mA (DC)
- Input impedance of 250 ohms.
- Signal output 0V - 10V (DC).
- Work with the power supply voltage of 5V DC.
- Ability isolation between power, input, and output max. 3000V (RMS).
--- Overall nonlinearity of less than 2%.b>ISO-Z1-W5-P3-O4 = isolated thermal resistance to voltage converter

Monday, November 12, 2012

MPT-200C - 200W +5V & +/-15V Medical Open Frame Power Supply


MPT-200C - 200W +5V & +/-15V Medical Open Frame Power Supply

Features
Input Voltage 90~264 VAC, 127~370VDC
Input Frequency 47~440Hz
Power Factor PF>0.95/230VAC PF>0.98/115VAC, full load
AC Input Current 3.5A at 115VAC, 60Hz or 1.6A at 230VAC, 60Hz full load
Inrush Current <25a 115vac="115vac" 230vac="230vac" at="at" cold="cold" or="or" p="p" start="start">Setup, Rise Time 1000ms, 20ms / 230VAC at full load , 3000ms, 20ms / 115VAC at full load
Hold-Up Time 16ms / 230VAC at full load, 16ms / 115VAC at full load
Leakage Current <180 264vac="264vac" at="at" earth="earth" for="for" leakage="leakage" p="p"><100 264vac="264vac" at="at" for="for" leakage="leakage" p="p" patient="patient">DC Output ADJ Range -5% to +10% rated output, on first output
Over Load Protection 120~160% rated load
Auto recovery once fault condition removed
Over Voltage Protection 115%~135% rated load, on first output
Over Temperature Protection At 95°C. Will shut down and recover automatically after temperature goes down
Power Good/Fail Signal TTL logic high for power good and TTL low for power fail
Remote Control RC+/RC-:0 ~ 0.8V=power on; 4 ~ 10V=power off sink current<4 ma="ma" p="p">Working Temperature -20°C to 70°C (refer to derating curve)
Working Humidity 20~90% RH non-condensing
Storage Temperature -40°C to +85°C
Storage Humidity 10~90% RH
Temperature Coefficient ±0.04%/°C (0~50°C) full load
Vibration 2G 10Hz ~500Hz 10 min cycle
Medical Safety Standards UL60601-1, TUV EN60601-1 approved
Commercial Safety Standards Complies with UL60950-1, TUV EN60950-1
Withstand Voltage I/P-O/P: 4000VAC I/P-FG, O/P-FG: 1500VAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG : >100M Ohms
EMI Compliance to EN55011 Class B, EN55022 Class B, EN61000-3-2, EN61000-3-3
EMS Compliance to EN61000-4-2 Level 3, 8KV, EN61000-4-2 Level 2, 4KV
EN61000-4-3 Level 2, 3V/m , EN61000-4-3 Level 3, 10V/m
EN61000-4-4 Level 2, 1KV/5KHz, EN61000-4-4 Level 3, 2KV/5KHz
EN61000-4-5 Level 4, 2KV/Line-Line, 4KV/Line-Earth
EN61000-4-6 Level 2, 3Vrms/m, Level 3, 10Vrms/m
EN61000-4-8 Level 2, 3A/m, EN61000-4-8 Level 3, 10A/m, EN61000-4-11 Compliance
ENV50204 Level 2, 3V/m, 900MHz, ENV50204 Level 3, 10A/m, 900MHz
MTBF 262,100 hours min MIL-HDBK-217F
Dimensions 177.8 x 107.2 x 35.5mm

MPT-200C output Specifications
Voltage (max/rated) Current (amps) Power (watts) R&N (mV) Efficiency (%)
5V 20A 200W 80mV 80%
15V 5A 150mV
-15V 2A 80mV

Meanwell Open Frame Swicthing Power Supply MPQ-200C

Meanwell Open Frame Swicthing Power Supply MPQ-200C
Quad Output AC/DC Medical Power Supply, Open Frame

Features:
Medical type
Free air convection for 140W & 200W with 25CFM forced air
Low leakage current < 180
Power good and power fail signal output
Built-in remote ON/OFF control
Built-in remote sense function
Built-in active PFC, PF>0.95@230VAC
Universal AC input/Full range
Protections: Short circuit/Over load/Over voltage/Over temp.
UL2601-1 medical safety approved
100% full load burn-in test
Dimensions(L*W*H) 177.8mm*108mm*35.5mm


Output Specifications:
Output #1
Voltage #1: 5 Volts DC
Min Current #1: 3 Amps
Max Current #1: 15 Amps
Output #2
Voltage #2: 15 Volts DC
Min Current #2: 0.5 Amps
Max Current #2: 5 Amps
Output #3
Voltage #3: -5 Volts DC
Min Current #3: 0 Amps
Max Current #3: 2 Amps
Output #4
Voltage #4: -15 Volts DC
Min Current #4: 0 Amps
Max Current #4: 2 Amps
Total Power: 80 Watts
Total Power: 200 Watts
Input Specifications:
Input Voltage: 90~264VAC

Meanwell Open Frame Swicthing Power Supply LPS-100-24


Meanwell Open Frame Swicthing Power Supply LPS-100-24
AC/DC Power Supply Single-OUT 24V 4.2A 100.8W 13-Pin 

Specifications for LPS-100-24

  • Manufacturer Mean Well
  • Part No: LPS-100-24
  • RoHS: Yes
  • Efficiency: 80(Typ) %
  • Input Frequency: 47 to 63 Hz
  • Family: LPS-100
  • Supplier_Package: N/A
  • Packaging: N/A
  • Input Voltage: 88 to 132,176 to 264 V
  • Output Voltage: 24VDC / 4,2Amp / 100.8 Watt
  • Pin_Count: 13
  • Mounting: Screw
  • Minimum Isolation Voltage: 3000 VAC
  • Operating Temperature: -10 to 60 °C

Friday, November 09, 2012

APPA 55 II Digital Contact Thermometer

APPA 55 II Digital Contact Thermometer


Features


  • Triple 4 digit large LCD display shows  any combination of T1, T2, T1-T2 plus MIN, MAX and AVG.
  • MIN, MAX, and AVG display with Real Time Stamp
  • Auto Calibration with excellent accuracy
  • Measure K, J-Types of thermocouples
  • Selectable degC, degF or K reading
  • Easy to use panel design
  • Data logging up to 16,000 records 
  • Optical RS-232 interface
  • Auto Power Off with selectable time setting
  • Protective Holster with tilt stand
  • Two Bead probes included for Dual thermocouple input
  • Win DTM50 software (Optional)
  • usb cable for computer interfacing (Optional)

ATTEN APS3005S 30V 5Amp


ATTEN APS3005S 30V 5Amp


Ideal for Educational Laboratories. Safe for students to use
0.01% High Regulation
Load Stability ≤ 0.3% (Test Conditions 30V / 3A)
  • Digital Display Resolution Voltage 0.1V Current 0.01A
  • Protection Methods 
  • Current Limited Lower Voltage
  • Short Circuit Protection
  • Over-Temperature Protection
  • High-pressure Test
  • Leakage Current ≤ 1ma (Test Conditions: Input-To-Ground 1700VAC/2s)
  • Insulation Resistance ≥ 7MΩ (Test Conditions: Input-To-Ground 500VDC/5s)
  • Work Method Constant-Current Constant-Voltage
  • Cooling Method Strong Wind Cooling
  • Working Environment 0-40 ℃; Relative Humidity <80 span="span">
  • Storage Temperature -20-80 ℃ Relative Humidity <80 span="span">
  • Size 260 * 150 * 160 (L * W * H)