Showing posts with label Multimeter. Show all posts
Showing posts with label Multimeter. Show all posts
Friday, January 12, 2018
Wednesday, October 04, 2017
Uni-T UT202A Auto-Ranging AC DC 600 Amps Auto/Manual Range Digital Handheld Clamp Meter
UNI-T UT202A is a 3 1/2 digit digital clamp meter with stable, reliable, and secure performance. Equipped with a double LSI as the core, an internal ADC converter, as well as overload protection make excellent performance for measurement applications of various electronic instruments.
UNI-T UT202A you can use to measure DC voltage, AC voltage, resistance, diode, AC current, and so forth.
Specification:
- AC current: 20 A / 200 A / 600 A ± (1.5% + 5)
- AC Voltage: 2V / 20V / 200V / 600V ± (1.2% + 5)
- DC voltage: 200 mV / 2 V / 20 V / 200 V / 600 V ± (0.8% + 1)
- Resistance: 200/2 K / 20 K / 200 K / 2M / 20M Ohm ± (0.8% + 3)
- Display: LCD
- Power Supply: 1x 9V 6F22
- Maximum Conductor Diameter: 26 mm
- Dimensions: 210 mm x 75.6 mm x 30 mm
- Red
- Features: Equipped with carier bag, pair of probes, and guide book
Thursday, November 24, 2016
Fluke 9040 Phase Rotation Indicator
Fluke 9040 Phase is a phase rotation gauge on the motor, driver, and an electronic system that uses 3-phase voltage. Fluke 9040 measurement results effectively through the LCD display. Fluke 9040 is perfect when applied to commercial industry because it can be used on the working voltage range of 40 V to 700 V and the measurement probe has also been equipped with industry-standard security.
specifications:
- Working Voltage: 40-700 V
- Power Supply: Drawn from the unit tested
- Frequency range: 15-400 Hz
- Timer Operations: Sustainable
- Work tempratur: 0 ° C - 40 ° C
- Resistance Dust / Water: IP 40
- Safety Standards: EN 61010, EN 61557-7
- Dimensions: 124 x 61 x 27 mm
- Weight: 208.8 g
Friday, October 28, 2016
APPA 205 desktop multimeter
APPA 205 Bench Instrument
- 4000 count large scale digital display
- 42 segment analog bargrah display
- True-RMS
- Autoranging and Manual selection
- AC/DC Dual Power Sources
- Backlight
- Data Hold
- Diode and Continuity Test
- Frequency counter, Capacitance
- Min/Max Hold
- Relative Mode
- Store, Recall function
- 6KV transients protection on 660 VAC feeders
- Conformed to meet UL 3111 and IEC
- 10101-1 Specification
APPA 203 desktop multimeter
APPA 203 Bench Instrument
- 4000 count large scale digital display
- 42 segment analog bargrah display
- Autoranging and Manual selection
- Backlight
- AC/DC Dual Power Sources
- Data Hold
- Diode and Continuity Test
- Frequency counter, Capacitance
- Min/Max Hold
- Relative Mode
- 6KV transients protection on 660 VAC
- feeders
- Conformed to meet UL 3111 and IEC
- 10101-1 Specification
Thursday, June 30, 2016
DEKKO HS-2203 Three Phase Digital Power Clamp Meter
DEKKO HS-2203 Three Phase Digital Power Clamp Meter
Features :
- Auto Power Off
- Auto Ranging
- Max/min
- Data Hold
- Display Back Light
- Jaw Opening Ø50 mm / 2.0”
- Data Logging and Recall 28 Groups
- LBD Low Battery Indication
- True RMS True Root Mean Square Measurement
- Display 9999 Counts
- RS232 Interface
Specifications
HS 2203
|
RANGE
|
ACCURACY
|
| AC Voltage | 0.1 ~ 600V | ±(1.2%+5) |
| AC Current | 0.1A ~ 1000A | ±(2.0%+5) |
| Active Power | 0.1kW ~ 600kW | ±(3.0%+5) |
| Apparent Power | 0.1kVA ~ 600kVA | ±(3.0%+5) |
| Reactive Power | 0.1kVAr ~ 600kVAr | ±(4.0%+5) |
| Power Factor | 0.3 ~ 1 | ±(0.02%+2) |
| Active Energy | 0.001kWh ~ 10000kWh | ±(3.0%+2) |
| Frequency | 20Hz ~ 1000Hz | ±0.5% |
| General | ||
| Power Supply | 4 x 1.5V AA Batteries | |
| Product Size | 300mm x 103mm x 51mm (11.8” x 4.1” x 2.0”) | |
| Product Weight | 640g (1.4lb) | |
| Category | CE CAT. III 600V RoHS | |
Tuesday, June 14, 2016
Fluke 117 Electrician's Multimeter with Non-Contact voltage
Compact true-rms meter for commercial applications. The Fluke 117 is the ideal meter for demanding settings like commercial buildings, hospitals and schools. The 117 includes integrated non-contact voltage detection to help get the job done faster.
Also check out the Fluke 114 Electrical Multimeter, the Fluke 115 Multimeter, and the Fluke 116 HVAC Multimeter with Temperature and Microamps.
- VoltAlert™ technology for non-contact voltage detection
- AutoVolt automatic ac/dc voltage selection
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- True-rms for accurate measurements on non-linear loads
- Measures 10 A (20 A overload for 30-seconds)
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak™) for hands free operation
- CAT III 600 V safety rated
Model includes the following:
Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. 2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
| ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Fluke 116 Digital Multimeter Specifically designed for HVAC professionals
With the ability to take temperature and microamp measurements, the Fluke 116 Digital Multimeter has everything you need to help you quickly troubleshoot problems with HVAC equipment and flame sensors. The Fluke 116 measures resistance, continuity, frequency and capacitance. Fluke 116 multimeters are independently tested for safe use in CAT III 600 V Environments.
- Built-in thermometer for HVAC applications
- Microamps to test flame sensors
- Low input impedance: helps prevent false readings due to ghost voltage
- Large white LED backlight to work in poorly lit areas
- Resistance, continuity, frequency and capacitance
- Min/Max/Average with elapsed time to record signal fluctuations
- Compact ergonomic design for one-handed operation
- Compatible with optional magnetic hanger (ToolPak™)
- CAT III 600 V safety rated
Includes:
- 4 mm silicone test lead set
- 80BK Integrated Temperature probe
- Holster
- Installed 9 V battery
- User manual
| Specifications | ||
| Maximum voltage between any terminal and earth ground | 600 V | |
| Surge protection | 6 kV peak per IEC 61010–1 600 VCAT III, Pollution Degree 2 | |
| Display | Digital: 6,000 counts, updates 4 per second | |
| Bar graph | 33 segments, updates 32 per second | |
| Operating temperature | -10°C to + 50°C | |
| Storage temperature | -40°C to + 60°C | |
| Battery type | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 | |
| Battery life | 400 hours typical, without backlight | |
| Accuracy Specifications | ||
| DC millivolts | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| DC volts | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.00 V / 0.1 V |
| Accuracy | ±([% of reading] + [counts]): 0.5% + 2 | |
| Auto volts | Range/resolution | 600.0 V / 0.1 V |
| Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) | |
| AC millivolts1 True RMS | Range/resolution | 600.0 mV / 0.1 mV |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
| AC volts1 True RMS | Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) | |
| Continuity | Range/resolution | 600 Ω / 1 Ω |
| Accuracy | Beeper on < 20 Ω, off > 250 Ω detects opens or shorts of 500 μs or longer. | |
| Ohms | Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
| Accuracy | 0.9% + 1 | |
| Range/Resolution | 40.00 MΩ / 0.01 MΩ | |
| Accuracy | 5% + 2 | |
| Diode Test | Range/resolution | 2.00 V / 0.001 V |
| Accuracy | 0.9% + 2 | |
| Capacitance | Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
| Accuracy | 1.9% + 2 | |
| Range/resolution | > 1000 μF | |
| Accuracy | 5% + 20% | |
| Lo-Z Capacitance | Range | 1 nF to 500 μF |
| Accuracy | 10% + 2 typical | |
| Temperature² (Type-K thermocouple) | Range/resolution | -40°C to 400°C / 0.1°C |
| Accuracy | 1% + 10² | |
| Range/resolution | -40°F to 752°F / 0.2°F | |
| Accuracy | 1% + 18² | |
| AC μA true-rms (45 Hz to 500 Hz) | Range/resolution | 600.0 μA / 0.1 μA |
| Accuracy | 1.5% + 3 | |
| DC μamps | Range/resolution | 600.0 μA / 0.1 μA |
| Accuracy | 1.0% + 2 | |
| Hz (V or A input)² | Range/resolution | 99.99 Hz / 0.01 Hz 999.99 Hz / 0.1 Hz 9.999 Hz / 0.001 Hz 50.00 Hz / 0.01 Hz |
| Accuracy | 0.1% + 2 | |
| 1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V. 2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3. Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current. 4. Temperature Range/Resolution: -40°F to 752°F / 0.2°F. | ||
| Mechanical and General Specifications | ||
| Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) | |
| Weight | 550 g | |
Friday, May 06, 2016
SANWA PM3 pocket digital multimeter
PM3 Sanwa Digital Multimeter, which is used to measure current, voltage and resistance electric accurately. PM3 Sanwa coming from Japan this has features that are easy and quick measurement of capacitance.
Measurement frequency (AC sine wave).
Features a mode switch off (turn off) automatic (15 min) (Cancelled).
Safety standard IEC61010-1 owned CAT.II DC AC500V Max.
■3-3 / 4 digits 4000 count
■0.7% best accuracy
■Capacitance measurement
※Not suitable for measurement of condensers with large leak current.
■Frequency measurement (AC sine wave only)
■Duty cycle
■Data hold
■Relative value
■Auto power off (15min.) (cancelable)
Display : numeral display 4000
Sampling rate : 3 times / sec.
AC frequency bandwidth : 40〜400Hz
Monday, April 04, 2016
Fluke 87V/E2 Industrial Electrician Combo Kit
This combo kit is built around the Fluke 87V, the most widely used industrial digital multimeter in the world, and includes special accessories to make you even more productive on the job. This kit will save over 15% compared with the individual price of all the accessories. Plus you'll be working with the most trusted tools in the world.
Features
Electrical safety
All inputs are protected to the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600 V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals
Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.
Unique function for accurate measurements of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals
Accurately measure the frequency (motor speed). Frequency measurement not affected by the ASDs carrier frequency
Measure AC current with an optional current clamp accessory
Compare reading from the 87V with the display on the ASD
Special shielding blocks high frequency, high-energy noise generated by large drive systems
Features
- Unique function for accurate voltage and frequency measurements on adjustable speed motor drives and other electrically noisy equipment
- Built-in thermometer conveniently allows you to take temperature readings without having to carry a separate instrument
- Optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks
- Large digit display with bright, two-level backlight makes the 87V significantly easier to read than older models
- True-rms ac voltage and current for accurate measurements on non linear signals
- Selectable filter for accurate voltage and frequency measurements on motor drives
- 0.05% DC accuracy
- 6000 counts, 3-3/4 digits
- 4-1/2 digit mode for precise measurements (20,000 counts)
- Measure up to 1000 V AC and DC
- Measure up to 10 A, 20 A for up to 30 seconds
- Built in thermometer lets you carry one less tool (TC probe included)
- Frequency to 200 kHz and % duty cycle
- Resistance, continuity and diode test
- 10,000 µF capacitance range for components and motor caps
- Min/Max-Average recording with Min/Max Alert to capture variations automatically
- Peak capture to record transients as fast as 250 µs
- Relative mode to remove test lead interference from low ohms measurements
- Auto and manual ranging for maximum flexibility
- Touch Hold to capture stable readings avoiding noisy signals
- Large display digits and two-level bright white backlight for increased visibility
- Analog bargraph for fast changing or unstable signals
- Input Alert provides audible warning against wrong use of input jacks
- Improved selectable sleep mode for long battery life
- Access door for fast battery changes without breaking the calibration seal
- "Classic" design with new removable holster with built in test lead and probe storage
Electrical safety
All inputs are protected to the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600 V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals
Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.
Unique function for accurate measurements of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals
Accurately measure the frequency (motor speed). Frequency measurement not affected by the ASDs carrier frequency
Measure AC current with an optional current clamp accessory
Compare reading from the 87V with the display on the ASD
Special shielding blocks high frequency, high-energy noise generated by large drive systems
Specifications Voltage DC Maximum Voltage 1000 V Accuracy ±(0.05% + 1) Maximum Resolution 10 µV Voltage AC Maximum Voltage 1000 V Accuracy ±(0.7% + 2) True RMS AC Bandwidth 20 kHz with low pass filter; 3 db @ 1 kHz Maximum Resolution 0.1 mV Current DC Maximum Amps 10 A (20 A for 30 seconds maximum) Amps Accuracy ±(0.2% + 2) Maximum Resolution 0.01 µA Current AC Maximum Amps 10 A (20 A for 30 seconds maximum) Amps Accuracy ±(1.0% + 2) True RMS Maximum Resolution 0.1 µA Resistance Maximum Resistance 50 MΩ Accuracy ±(0.2% + 1) Maximum Resolution 0.1Ω Capacitance Maximum Capacitance 9,999 µF Accuracy ±(1% + 2) Maximum Resolution 0.01 nF Frequency Maximum Frequency 200 kHz Accuracy ±(0.005% + 1) Maximum Resolution 0.01 Hz Duty Cycle Maximum Duty Cycle 99.9% Accuracy ±(0.2% per khz +0.1%) Maximum Resolution 0.1% Temperature Measurement -200.0°C - 1090°C
-328.0°F - 1994.0°F
excluding probe80 BK Temperature Probe -40.0°C - 260°C
-40.0°F - 500°F, 2.2°C or 2% whichever is greaterConductance Maximum Conductance 60.00 nS Accuracy ±(1.0% + 10) Maximum Resolution 0.01 nS Diode Range 3 V Resolution 1 mV Accuracy ±(2% + 1) Duty Cycle Range Accuracy Within ±(02% per kHz +0.1%) Environmental Specifications Operating Temperature -20°C to +55°C Storage Temperature -40°C to +60°C Humidity (Without Condensation) 0% - 90% (0°C - 35°C)
0% - 70% (35°C - 55°C)Operating Altitude 2000 m Safety Specifications Overvoltage category EN 61010-1 to 1000 V CAT III, 600V CAT IV Agency Approvals UL, CSA, TÜV, VDE listed Mechanical and General Specifications Size 201 x 98 x 52 mm (with holster) Weight 355 g
624 g - with holsterDisplay Digital 6000 counts updates 4/sec.
19,999 counts in high-resolution modeAnalog 32 segments, updates 40/sec. Frequency 19,999 counts, updates 3/sec at > 10 Hz Warranty Lifetime Battery Life Alkaline ~400 hours typical, without backlight Shock 1 Meter drop per IEC 61010-1:2001 Vibration Per MIL-PRF-28800 for a Class 2 instrument
Subscribe to:
Posts (Atom)











